Error description

  • ABENDS0C4 possible when Q Capture is processing the stop
    or reinit command with a global transaction.
    

Local fix

  • restart capture.  abend should not occur on restart.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 1- SQL Apply                                 *
    *                 2- SQL Apply                                 *
    *                 3- Q Capture                                 *
    *                 4- Q Capture                                 *
    *                 5- v8 asntdiff users                         *
    *                 6- Q Capture                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1- Apply fails with incorrect message   *
    *                      when col_type in asn.ibmsnap_subs_cols  *
    *                      contains invalid value                  *
    *                      2- applytrail contains no error         *
    *                      information when Apply failed to        *
    *                      connect to target                       *
    *                      3- Restart info was not saved when      *
    *                      Capture got a STOP signal               *
    *                      4- QCapture gets 0C4 while processing   *
    *                         STOP or REINIT command               *
    *                                                              *
    *                                                              *
    *                      5- ASNTIDFF EDC5133I error with table
    *                      that has more than 9 million rows.
    *                      6- Invalid restart message check on     *
    *                      capture server name prevented           *
    *                      customers in data sharing from          *
    *                      starting Capture                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    1- Apply fails with incorrect message when col_type in
    asn.ibmsnap_subs_cols contains invalid value
    2- applytrail contains no error information when Apply failed
    to connect to target
    3- MAXCMTSEQ was not saved thus Capture read the STOP signal
    again upon restart
    4- Transmgr destructor attempts to delete global subtrans from
    the minLSN chain
    5- 92 million rows caused negative index in to the keyblock
    array
    6- Remove the invalid check in the restart message for warm
    start
    

Problem conclusion

  • 1- issue message ASN1036 when col_type is invalid
    2- issue message ASN1003 in applytrail if Apply can not connect
    to target server
    3- Capture now saves the restart info when stopping
    4- global subtrans will be deleted when global anchor trans are
    deleted.
    5- fixed the negative indexing by not using the macro
    6- Check is now removed
    

Temporary fix

Comments

APAR Information

  • APAR number

    PK38132

  • Reported component name

    WS REPLICATION

  • Reported component ID

    5655L8800

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2007-01-25

  • Closed date

    2007-02-08

  • Last modified date

    2007-03-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    JR25824 UK21978 UK21979 UK21980 UK21981

Modules/Macros

  •    ASNACMD  ASNADMSP ASNAMAN  ASNAPPLY ASNAPRS
    ASNCAP   ASNCCMD  ASNMCMD  ASNMIG8  ASNMON   ASNPLXFY ASNQACMD
    ASNQAPP  ASNQCAP  ASNQCCMD ASNQDEP  ASNQMFMT ASNQWK   ASNRBASE
    ASNTDAPI ASNTDIFF ASNTRC   ASNTREP  ASNTXS
    

Fix information

  • Fixed component name

    WS REPLICATION

  • Fixed component ID

    5655L8800

Applicable component levels

  • R820 PSY UK21978

       UP07/02/17 P F702

  • R821 PSY UK21979

       UP07/02/17 P F702

  • R822 PSY UK21980

       UP07/02/17 P F702

  • R823 PSY UK21981

       UP07/02/17 P F702

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSDP5R","label":"InfoSphere Replication Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"820","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date:
23 March 2007