PJ40805: ZCDCO D F PROBLEM WITH OUTPUT DISPLAY MESSAGE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • See Problem Summary.
    

Local fix

  • na
    

Problem summary

  • APAR NUMBER:  PJ40805
    PRODUCT:  z/TPF
    FUNCTIONAL AREA:  CONTINUOUS DATA COLLECTION (CDC)
    SHIPPED IN PUT:  10
    
    ABSTRACT:
    ZCDCO DISPLAY FREQUENCY problem with output display message
    with PJ31435 applied.
    
    PACKAGE CONTENTS:
    Source Segments:
    (C) base/rt/cdco.c
    
    Object Only Binaries:
    None.
    
    Configuration Independent Binaries:
    (C) base/obj/cdco.o
    (C) base/load/CDCO.so
    
    Support Files:
    base/lst/cdco.lst
    base/lst/CDCO.map
    
    OTHER BINARIES TO BUILD: NO
    None.
    
    COMMENTS:
    The problem is when the ZCDCO DISPLAY FREQUENCY command is
    entered, a wtopc("END OF
    DISPLAY",WTOPC_EBROUT,WTOPC_CHAIN_END,WTOPC_NO_HEADER) is
    executed twice for the output display message.
    
    The code that builds the output display message is in the
    zcdcoDisplay function in source file cdco.c. The first
    execution of the wtopc occurs if the ZCDCO DISPLAY command
    includes the FREQUENCY option. The second execution of the
    wtopc occurs at the end of the zcdcoDisplay function for all
    ZCDCO DISPLAY commands, whether the FREQUENCY option was
    included on the command line or not.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PJ40805

  • Reported component name

    Z/TPF

  • Reported component ID

    5748T1501

  • Reported release

    110

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-12-20

  • Closed date

    2013-01-04

  • Last modified date

    2013-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    Z/TPF

  • Fixed component ID

    5748T1501

Applicable component levels

  • R110 PSY

       UP