Problem summary
APAR NUMBER: PJ40772 PRODUCT: z/TPF FUNCTIONAL AREA: TAPE I/O AND ERROR RECOVERY SHIPPED IN PUT: 10 ABSTRACT: When there is a timeout on a write operation issued to the dump tape then the dump is aborted and no tape switch occurs. PACKAGE CONTENTS: Source Segments: (C) base/cp/cedt.cpy Object Only Binaries: None. Configuration Independent Binaries: None. Support Files: None. OTHER BINARIES TO BUILD: YES (C) <sys>/obj/cccpse.o (C) <sys>/load/CPS0.so COMMENTS: If a system error occurs that requires writing more data than will fit into the Dump Buffer Area then CCCPSE must write some of that data directly to the tape instead of letting it remain in the DBA. If one of these writes fails because the write command does not complete in the allocated amount of time then the dump is aborted and no tape switch occurs. This leaves a potentially unusable device as the active dump tape and subsequent attempts to use the drive can result in the same failure.
Problem conclusion
SOLUTION: Segment CEDT in CSECT CCCPSE has been updated so that a tape switch will be attempted if a timeout occurs on a write operation to the dump tape. COREQS: NO None. MIGRATION CONSIDERATIONS: NO None. BUILD COMMANDS AND INSTRUCTIONS: YES #maketpf commands for linux maketpf -f CPS0 cccpse.o maketpf CPS0 link UPDATED INFORMATION UNITS: NO None. See your IBM representative if you need additional information. DOWNLOAD INSTRUCTIONS: http://www.ibm.com/software/htp/tpf/maint/maintztpf.html APAR URL: http://www.ibm.com/software/htp/tpf/ztpfmaint/put10/PJ40772.htm
Temporary fix
Comments
APAR Information
APAR number
PJ40772
Reported component name
Z/TPF
Reported component ID
5748T1501
Reported release
110
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-04
Closed date
2013-04-10
Last modified date
2013-04-10
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
Z/TPF
Fixed component ID
5748T1501
Applicable component levels
R110 PSY
UP
Rate this page:
Average rating
Copyright and trademark information
IBM, the IBM logo and ibm.com are trademarks of International Business Machines Corp., registered in many jurisdictions worldwide. Other product and service names might be trademarks of IBM or other companies. A current list of IBM trademarks is available on the Web at "Copyright and trademark information" at www.ibm.com/legal/copytrade.shtml.