IBM Support

PI99104: ABEND0C4 IN FAULT ANALYZER MODULE IDIDA, JAVA INFORMATION MISSING FROM THE INTERACTIVE REANALYSIS REPORT.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • An abend0C4 in Fault Analyzer (FA) module IDIDA, problem
    symptom may differ depending on the use of the FA ZZDEBUG
    option. With ZZDEBUG, the abend S0C4 will likely occur on a
    sprintf call in function csectKeyFmt.  Without ZZDEBUG, the
    S0C4 will likely occur in PrtLblData.  Variants are possible
    though, depending of the starting address and storage layout at
    the time.
    
    During processing to determine a compile unit name, an invalid
    address was used that unfortunately pointed to valid storage
    that apparently had earlier been owned by LE but since freed.
    Because of the use of the LE run-time option
    STORAGE(DB,EB,NONE,8192), which caused the storage to be
    set to all X'EB', and the use of the Fault Analyzer option
    LOCALE(De_DE.IBM-1141), which resulted in X'EB' being considered
    a printable character, no invalid or terminating character was
    found until the length had exceeded the maximum that was able
    to be handled.
    Additional symptom - the Java information option will not appear
    in the FA Interactive Reanalysis Report.
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Closed as DUP of Miscellaneous Bug Fixes APAR PI96533
    

APAR Information

  • APAR number

    PI99104

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655Q1100

  • Reported release

    D10

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-06-13

  • Closed date

    2018-06-21

  • Last modified date

    2018-06-21

  • APAR is sysrouted FROM one or more of the following:

    PI97668

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: