IBM Support

PI98909: COBOL v5.2 to v6.2 fail to produce diagnostic IGYPG3173-W for compares whose results are known at compile time

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • COBOL v4.2 produced the diagnostic
    
        IGYPG3173-W The result of the comparison of operands
            {operand-1} and {operand-2}  is known at compile time,
            based on the attributes of the  operands. Unconditional
            code was generated.
    
    when it was known that {operand-1} and {operand-2} could not
    possibly be (not) equal, a situation that indicates a
    programming error.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V5.2 compiling     *
    *                 programs containing alphanumeric or          *
    *                 national EQUAL or NOT EQUAL comparisons      *
    *                 where one of the operands is an              *
    *                 alphanumeric or national literal, where the  *
    *                 length of the literal is longer than the     *
    *                 other operand and at least one of the        *
    *                 extraneous characters of the literal are     *
    *                 non-blank (non-padding).                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: Incorrect output: The Enterprise COBOL  *
    *                      V5.2 compiler would fail to emit a      *
    *                      warning message when the result of the  *
    *                      comparison described above is known at  *
    *                      compile time.                           *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    COBOL V5/6 users would like to be warned by the compiler if the
    result of an EQUAL or NOT EQUAL comparison between an
    expression and an alphanumeric or national literal can be
    determined at compile time, specifically when the literal is
    longer than the other operand and the extraneous characters
    contain non-blanks (no padding) characters.  These warnings are
    emitted by the Enterprise COBOL V4 compiler, but not previously
    by the V5/6 compiler.
    

Problem conclusion

  • The compiler is changed to issue a new compile time warning
    message for the situation described above.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI98909

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655W3200

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-06-07

  • Closed date

    2018-06-10

  • Last modified date

    2018-07-02

  • APAR is sysrouted FROM one or more of the following:

    PI98771

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCBE   IGYCCBE  IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG
    IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5
    IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0
    IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D
    IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1
    IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYECWI  IGYMSGE  IGYMSGK  IGYMSGT
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655W3200

Applicable component levels

  • R520 PSY UI56404

       UP18/06/21 P F806

  • R521 PSY UI56405

       UP18/06/22 P F806

  • R522 PSY UI56406

       UP18/06/22 P F806

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
02 July 2018