IBM Support

PI94300: EVENTS NUMBER THRESHOLD PARAMETRIZATION FOR EQQN059I MESSAGE

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as new function.

Error description

  • Events number threshold for EQQN059I message should be
    customizable.
    Currently hardcoded value for the counter is 400 reapplied
    events. After every 400 events a message EQQN059I is issued.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IWSz 930 and TWSz 920 users running      *
    *                 event re-apply.                              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Message EQQN059I is issued every 400    *
    *                      re-applied events, in case the events   *
    *                      re-apply occurs.                        *
    ****************************************************************
    When the re-apply of the events occurs, the message EQQN059I is
    normally issued.
    There is no way to customize the processed events number
    threshold that triggers the message EQQN059I. Currently
    hard-coded value for the counter is 400, meaning every 400
    re-applied events.
    

Problem conclusion

Temporary fix

Comments

  • Code has been changed to select the number of re-applied events
    after which the message EQQN059I is issued.
    A new parameter REAPPLYCOUNT(nnnnn) has been added in OPCOPTS
    to select the number of re-applied events, after which the
    message EQQN059I is issued.
    THE FOLLOWING IWS and TWS FOR Z/OS PUBLICATION WILL BE UPDATED:
                               - - -
    +-------------------------------------------------------------+
    !TITLE: IBM Workload Scheduler for z/OS                       !
    !           Customization and Tuning                          !
    !       Tivoli Workload Scheduler for z/OS                    !
    !           Customization and Tuning            SC32-1265-09  !
    !-------------------------------------------------------------!
    !Chapter 1. Defining Initialization Statements                !
    !Section: JTOPTS statement                                    !
    !                                                             !
    !Add the REAPPLYCOUNT new parameter in the diagram and in the !
    !description:                                                 !
    !                                                             !
    ! >--+-------------------------------------+-->               !
    !    !                                     !                  !
    !    !                    +--- 400 ---+    !                  !
    !    !                    !           !    !                  !
    !    +--REAPPLYCOUNT----(-+-- nnnnn --+-)--+                  !
    !                                                             !
    !                                                             !
    ! REAPPLYCOUNT(nnnnn ! 400)                                   !
    ! Defines after how many re-applied events the message        !
    ! EQQN059I is issued.                                         !
    ! Valid values are in the range between 1 and 32000. The      !
    ! default is 400.                                             !
    +-------------------------------------------------------------+
    

APAR Information

  • APAR number

    PI94300

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    922

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-02-26

  • Closed date

    2018-04-20

  • Last modified date

    2018-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI55357 UI55358 UI55359 UI55360

Modules/Macros

  • EQQBKRST EQQNMRST EQQZ25   EQQZOPTX
    

Publications Referenced
SC32126509    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R920 PSY UI55357

       UP18/04/28 P F804

  • R922 PSY UI55358

       UP18/04/28 P F804

  • R930 PSY UI55359

       UP18/04/28 P F804

  • R932 PSY UI55360

       UP18/04/28 P F804

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"922","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"922","Edition":"","Line of Business":{"code":"","label":""}}]