IBM Support

PI93835: ABEND S0C4-11 AT EQQWARSA+542 WHEN DYNAMICADD(NO) IN CONTROLLER RESOPTS AND DYNAMICADD(YES) IN BATCHOPT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • With DYNAMICADD(NO) coded in the controller RESOPTS and
    BATCHOPT having DYNAMICADD(YES) which is the default value,
    an operation is defined with a special resource that does not
    exist in the RD or CX and then an LT batch job is run.
    The operations is added into the CP in an ad-hoc
    manner (for instance as part of an application that
    is added to the CP via the 5.1 panel)
    
    The following abend is seen in the controller:
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
    
     PSW AT TIME OF ERROR  478D3000   A1524E30  ILC 4  INTC 11
     ACTIVE LOAD MODULE           ADDRESS=214CD000  OFFSET=000
     NAME=EQQWATOP
      DATA AT PSW  21524E2A - 000358C0  A0485829  C010BF9F
      AR/GR 0: 00000000/0000170B   1: 00000000/0021C1B8
            2: 0105003D/20556560   3: 00000000/0021A000
            4: 00000000/205CED80   5: 00000000/206DE100
            6: 00000000/0021B420   7: 00000000/00000000
            8: 00000000/205CED80   9: 00000000/FFFFFFE8
            A: 00000000/1FAC2AC0   B: 00000000/A15248F8
            C: 00000000/205AD000   D: 00000000/0021C160
            E: 00000000/A1524DB6   F: 00000000/A150A140
    Note that the value for register 9 is negative.
    The following messages are seen in the controller EQQMLOG:
    EQQW533E THE WSA TASK WILL ATTEMPT TO RECOVER FROM A SEVERE
    ERROR
    EQQW533I REFER TO THE SYSUDUMP DATA SET FOR MORE INFORMATION
    EQQW532E THE WSA TASK IS TERMINATING DUE TO A SEVERE ERROR.
    EQQW532I REFER TO THE SYSUDUMP DATA SET FOR MORE INFORMATION
    EQQZ045E SUBTASK WS ANALYZER      ENDED UNEXPECTEDLY
    .
    Note the same abend could occur if DYNAMICADD(NO)
    is coded explicitly both in the controller RESOPTS
    and in the BATCHOPT.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All IWS for ZOS users using Special          *
    *                 Resource feature.                            *
    *                 FUNCTION=WSA                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When message EQQQ510W is issued on      *
    *                      Controller MLOG indicating that a       *
    *                      Special Resource is needed by an        *
    *                      operation in the plan but could not     *
    *                      be allocated due DYNAMICDEL values      *
    *                      (both in DP batch and Controller)       *
    *                      an abend could occur in WSA task        *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF fixing this APAR               *
    ****************************************************************
    Abend can occur in WSA task when it tries to allocate
    a Special Resource (EQQWARSA) if the Special Resource index
    in the CP operation record is 0.
    This can occur if DYNAMICADD is disallowed both in DP and
    Controller
    

Problem conclusion

  • A check has been added in EQQWARSA to avoid the ABEND.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI93835

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    932

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-02-15

  • Closed date

    2018-03-12

  • Last modified date

    2018-04-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI54386 UI54387 UI54388 UI54389

Modules/Macros

  • EQQWARSA
    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R602 PSY UI54386

       UP18/03/15 P F803

  • R912 PSY UI54387

       UP18/03/15 P F803

  • R922 PSY UI54389

       UP18/03/15 P F803

  • R932 PSY UI54388

       UP18/03/15 P F803

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"932","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"932","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date: