IBM Support

PI92415: MISCELLANEOUS BUG FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 13 users          *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. NUMCHECK compiler option not        *
    *                          evaluated.                          *
    *                          APAR PI92228                        *
    *                      02. IDIUTIL IMPORT of single fault      *
    *                          entry sometimes fails to delete the *
    *                          fault entry from the input history  *
    *                          file.                               *
    *                          APAR PI94248                        *
    *                      03. Fault Analyzer loop processing      *
    *                          C/C++ abend with DWARF side file.   *
    *                          APAR PI95494                        *
    *                      04. Fault Analyzer does not present     *
    *                          mismatch popup when COBOL md5       *
    *                          signature not recorded in fault     *
    *                          entry but is found in supplied      *
    *                          load module/side file.              *
    *                          APAR PI95486                        *
    *                      05. Listing prompt does not make it     *
    *                          clear that LANGX or DWARF can be    *
    *                          used with FA and COBOL V5 or later. *
    *                          APAR PI95485                        *
    *                      06. Fault Analyzer reports incorrect    *
    *                          source line when processing DWARF   *
    *                          for COBOL V5+ abend.                *
    *                          APAR PI92482                        *
    *                      07. ENV ABEND_MODULE_NAME is blanks     *
    *                          for CICS LE application.            *
    *                          APAR PI89407                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    01. FA does not produce the NUMCHECK compiler option in the
        analysis report.
    02. The method used for the deletion is not always reliable.
    03. New usage of DW_OP_IBM_wsa_addr op not currently supported.
    04. Mismatch pop-up was only appearing when md5 signature
        present in both fault entry and load module/side file.
    05. Listing prompt wording could be better.
    06. Not all relevant entries in line number table are being
        processed.
    07. Value is not being created in realtime exits.
    

Problem conclusion

  • 01. FA is changed to support the new Cobol compiler NUMCHECK
        option.
    02. A more reliable method is now used to delete the imported
        fault entry from the input history file.
    03. DW_OP_IBM_wsa_addr op now supported.
    04. Mismatch popup now appears when md5 signature missing from
        fault entry but present in load module/side file.
    05. Listing prompt wording (and help panels) improved.
    06. Additional line number table entries are now processed.
    07. CICS termination exits are changed to create the value from
        the TCA.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI92415

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655Q1100

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-01-14

  • Closed date

    2018-04-10

  • Last modified date

    2018-05-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI55133

Modules/Macros

  • IDICAFAT IDICASUB IDICCFND IDICOPYR IDICRXDX IDICRXEI IDICRXET
    IDICRXHC IDICSMF  IDICSPC  IDICUXCS IDICUXWR IDIDA    IDIDATST
    IDIGMAIN IDIHPMSG IDIJAGNQ IDIJAGNT IDIMCICS IDINDEX  IDIPDDIR
    IDIPDSCU IDIPH005 IDIPH214 IDIPHL01 IDISASUB IDISCJST IDISDB2P
    IDISDB2S IDISFPEX IDISIFND IDISJL   IDISJLD  IDISJLDQ IDISJLOG
    IDISJLQ  IDISLKUP IDISLOG  IDISMAIN IDISREG  IDISRFRD IDISTIME
    IDISUPDI IDISVIEW IDISWRAP IDISWRAQ IDIUOPT  IDIUTIL  IDIXAFMT
    IDIXCFMT IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCM70 IDIXCM71
    IDIXDSAC IDIXFA   IDIXGSPC IDIXGSPS IDIXLFMT
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655Q1100

Applicable component levels

  • RD10 PSY UI55133

       UP18/04/12 P F804

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 May 2018