A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 13 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. Memory leak in FA ISPF dialog. * * APAR PI80845 * * 02. Fault Analyzer ABEND0C4 when * * processing storage check failure * * hotspot. * * APAR PI81410 * * 03. System dump file is required for * * CICS entries, or message is issued * * stating Trace Block is not in dump. * * APAR PI82002 * * 04. ABEND282-20 when data set for * * listing prompt is left blank * * APAR PI81240 * * 05. AbendS913 for SDSNLOAD in * * subsystem in seen as ABENDS058 by * * caller * * APAR PI84050 * * 06. MSGIDI0063W after successive jobs * * caused space management * * APAR PI85753 * * 07. IDI0047S IBM Fault Analyzer * * internal abend S0C4. * * APAR PI86008 * * 08. ABEND378 RC14 during analysis. * * MSGCSV430I may be issued. * * APAR PI86145 * * 09. 0C9 in cob_rel_stg() when * * processing COBOL table indexes. * * APAR PI79221 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. Subsystem communication control block is not freed. 02. Fault Analyzer not process a CICS 64-bit trace file correctly. 03. Trace blocks were not properly stored in the minidump. During reanalysis the original system dump will be processed if available. If not then messages are issued. 04. RACF is called with a null data set name. 05. Subsystem did not perform any checks before attempting to read SDSNLOAD data set. 06. Subsystem was not being notified to update $$INDEX so successive jobs were getting copies of an old cache. 07. FA is not decoding an LE PPA2 correctly, producing a huge string length. This string overlays data in the report phase. 08. IDIXDCAP is in the wrong key to free storage. 09. Zero table stride causes divide by zero.
Problem conclusion
01. Subsystem control block is freed at FA dialog termination. 02. Fault Analyzer is changed to address the 64-bit trace properly. 03. Trace blocks are correctly stored in the minidump. 04. Listing prompt dialog no longer permits a blank entry for data set name. 05. Fault Analyzer subsystem now generates a message when a ddname for SDSNLOAD is not found or it does not have read access to the data set. 06. The subsystem is notified to refresh its copy of $$INDEX after space management. 07. FA is changed to decode the PPA2 correctly. 08. IDIXDCAP is changed to use the correct key for freemain. 09. Table stride corrected.
Temporary fix
Comments
APAR Information
APAR number
PI82452
Reported component name
FAULT ANALYZER
Reported component ID
5655Q1100
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-01
Closed date
2017-09-11
Last modified date
2017-10-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI50245
Modules/Macros
HADQD10J IDICAASM IDICABND IDICADYN IDICAFAT IDICALE IDICALOC IDICASUB IDICCFND IDICISA IDICNOTA IDICNOTR IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICRXLE IDICSDB2 IDICSMF IDICSPC IDICSSRB IDICSVCR IDICSV11 IDICSV12 IDICSV14 IDICSV15 IDICUXCS IDICUXWR IDIDA IDIDASUB IDIDATSA IDIDATST IDIECASB IDIGMAIN IDIGNTCE IDIGWEBB IDIHPMSG IDIJAGNQ IDIJAGNT IDIMCICS IDINDEX IDIOPTLM IDIPADIR IDIPASUB IDIPDA IDIPDDIR IDIPDSCU IDIPHL01 IDIPH005 IDIPH214 IDIPH248 IDIPIPV IDIPIPVS IDIPLT IDIPLTD IDIRFRDS IDISAMAN IDISAQUE IDISAREQ IDISASUB IDISCJST IDISDB2P IDISDB2S IDISFA IDISFPEX IDISIFND IDISISPF IDISJL IDISJLD IDISJLDQ IDISJLOG IDISJLQ IDISLEEP IDISLKUP IDISLOG IDISLRAC IDISMAIN IDISREG IDISRFRA IDISRFRD IDISSREQ IDISTIME IDISUPDI IDISVIEW IDISWRAP IDISWRAQ IDISXCFA IDIUGPDF IDIUTIL IDIWTSEL IDIXALGL IDIXALOG IDIXASUB IDIXCCEE IDIXCC52 IDIXCEE IDIXCE53 IDIXCE67 IDIXCE68 IDIXCE69 IDIXCE70 IDIXCE71 IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCM70 IDIXCM71 IDIXCX52 IDIXCX53 IDIXDCAP IDIXDSAC IDIXDUMP IDIXFA IDIXGSPC IDIXGSPS IDIXIPV IDIXIPV2 IDIXLFMT IDIXLINK IDIXOPT IDIXSNAP IDIXTSEL
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655Q1100
Applicable component levels
RD10 PSY UI50245
UP17/09/14 P F709
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 October 2017