PI82334: DEBUG TOOL , HOGAN: LOAD OF ASSEMBER MODULE AMODE64 FAILS.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • following is displayed in the Debug Tool log:
    /* You were prompted because the CEE33N  condition was raised in
     your         */
    /* program.
    */
    /* CEE33N is a severity or class 2 condition.
    */
    /* The operating system has generated the following message:
    */
    /*    CEE3191E An attempt was made to initialize an AMODE24
    application       */
    /* without using the ALL31(OFF) and STACK(,,BELOW) run-time
    options.          */
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Debug Tool users who debug programs in a     *
    *                 HOGAN environment.                           *
    ****************************************************************
    * PROBLEM DESCRIPTION: Debug Tool with HOGAN: load of assember *
    *                      module AMODE64 fails.                   *
    ****************************************************************
    * RECOMMENDATION: Install this service if your users debug     *
    *                 in a HOGAN environment.                      *
    ****************************************************************
    Debug Tool with HOGAN: load of assember module AMODE64 fails.
    

Problem conclusion

  • Problem resolved.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI82334

  • Reported component name

    DEBUG TOOL Z/OS

  • Reported component ID

    5655Q1000

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-06-01

  • Closed date

    2017-10-26

  • Last modified date

    2018-01-25

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI51496

Modules/Macros

  • EQA00ABE EQA00CIC EQA00CND EQA00LCM EQA0CINF EQA0SCL1 EQA0SCL2
    EQA0SRP1 EQA0SRP2 EQA10PRC EQA80VER EQAAFSPS EQADCCN0 EQAEV006
    EQALMA   EQAYSMMN
    

Fix information

  • Fixed component name

    DEBUG TOOL Z/OS

  • Fixed component ID

    5655Q1000

Applicable component levels

  • RD10 PSY UI51496

       UP17/10/30 P F710

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTQWA","label":"IBM Debug for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
25 January 2018