Error description
Customer makes use of RACF exit program ICHRIX01 to intercept passwordless signons. After applying CICS maintenance from RSU1606 to RSU1612, they began to receive messages: ICH408I USER(userid) GROUP(groupname) NAME(user_name) LOGON/JOB INITIATION - INVALID PASSWORD ENTERED AT TERMINAL termid IRR013I VERIFICATION FAILED. INVALID PASSWORD GIVEN. Problem is due to code added by PI74896 where Register 2 is reused, causing the pointer to installation data (INSTLN_PTR) to be lost. . Additional Symptom(s) Search Keyword(s): KIXREVSLD DFHXSSB INQUIRE_PASSWORD_DATA INQUIRE PASSWORD DATA
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users with PTF's UI44245, UI44247 * * or UI44253 applied. * **************************************************************** * PROBLEM DESCRIPTION: CICS Installation data not passed to * * RACF. * **************************************************************** If ESMEXITS=INSTLN is coded as a SIT parameter then CICS should pass Installation Data to the RACF ESM on the appropriate calls, it does this by using a register that addresses the installation data. The RACROUTE REQUEST=VERIFYX calls used for password verification and change password requests use a register that does not address installation data at all. The register contents was previously set up correctly but after PI70500 the compiler reused the register and in doing so invalidated it. As a consequence the RACF ICHRIX01 exit was unable to interpret the area it had received and the request failed.
Problem conclusion
UI44245 UI44247 UI44253 DFHXSSB has been modified and now correctly passes the address of the CICS installation data on the RACROUTE=VERIFYX calls.
Temporary fix
Comments
APAR Information
APAR number
PI79851
Reported component name
CICS TS Z/OS V5
Reported component ID
5655Y0400
Reported release
000
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-04-12
Closed date
2017-05-09
Last modified date
2017-06-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI47090 UI47091 UI47092
Modules/Macros
DFHXSSB
Fix information
Fixed component name
CICS TS Z/OS V5
Fixed component ID
5655Y0400
Applicable component levels
R000 PSY UI47092
UP17/05/15 P F705
R800 PSY UI47090
UP17/05/15 P F705
R900 PSY UI47091
UP17/05/15 P F705
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.3","Edition":"","Line of Business":{"code":"","label":""}}]