IBM Support

PI75494: Service for Debug Tool 13.1.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • --- Features ---
    
    -Allow store of STARTSTOP msgs in STARTSTOPMSGDSN in CICS
     environment.
    
    -Debug Tool IMS Transaction Isolation Facility: Implement
     DFSMSCE0 exit sharing.
    
    -Debug Tool IMS Transaction Isolation Facility: Add LIST
     capability to IMS Transaction Isolation Facility batch
     interface.
    
    --- End Features ---
    
    --- Service ---
    
    -ABEND in EQA00OHC+'20D8'x when using Debug Tool for COBOL V5
     or V6 and TEST(NOSOURCE) with SET FREQUENCY ON in a preference
     file.
     (PI74365 at 13.1)
    
    -Debug Tool Utility JCL Analyzer gets EQA3058E Symbolic name
     too long for long symbolic names and variables.
     (PI75129 at 13.1)
    
    -Possible ABENDS0C4 in EQA00EVH when running Debug Tool with LE
     parameter TEST(ERROR,,*,*), and no Terminal Interface Manager
     (TIM) session connected.
     (PI74537 at 13.1)
    
    -ABENDS0C4 in EQA00KBM+'10C2'x when debugging in remote debug
     session.
     (PI74572 at 13.1)
    
    -Short-on-storage (SOS) in CICS when debugging application with
     large EQALANGX file.
     (PI75071 at 13.1)
    
    -ABEND in EQA0SXUT+'5208'x with SET LIST BY SUBSCRIPT ON in
     remote debug session.
     (PI75101 at 13.1)
    
    -Memory view contains ???? when it should contain values.
     (PI75428 at 13.1)
    
    -Currently Debug Tool's exit EQAD3CXT will continue to allocate
     the EQAUOPTS DS even though no entry in the XREF table was
     found .
    
     + EQAU999I CROSS REFERENCE ENTRY NOT FOUND.  TRANSACTION ID
     IS:  TRANS9999
    
     The process should stop here so the following steps are not
     executed
    
     + EQAU999I PROFILE DATA SET NAME: JOHNS.DBGTOOL.EQAUOPTS
     + EQAU999E DATA SET ALLOCATION FAILED. DATA SET NAME IS:
     JOHNS.DBGTOOL.EQAUOPTS
     + EQAU999E DYNAMIC ALLOCATION RETURNED THE FOLLOWING
     INFORMATION:
     + EQAU999E RETURN CODE=00000004, REASON CODE=1708, INFO CODE=
     0002
    
     (PI76259 at 13.1)
    
    -Debug Tool Coverage Utility annotated listing for assembler
     truncated because of misidentified MACRO/MEND statement.
     (PI76617 at 12.1)
    
    -The input field pDsnStat in panel EQAPMPSL for Debug Tool is
     too short causing the DATASET NAME to be truncated in the
     Debug Tool IMS Transaction Isolation Facility.
     (PI77408 at 13.1)
    
    -Debug Tool does not show all of multiple CSECTS if
     configuration file with multiple commands is used.
     (PI77399 at 13.1)
    
    -Debug Tool IMS Transaction Isolation Facility uses delay debug
     option which conflicts with the EQAOPTS delay debug option.
     (PI80811 at 13.1)
    
    -Debug Tool fails with ABENDS0C4 in EQA0SBPP+'1C3E' in remote
     debug session start up.
     (PI78394 at 13.1)
    
    -Debug Tool program check at EQA00AEI+'9A6'x when run EQAWIVPB
     sample in remote debug mode.
     (PI78765 at 13.1)
    
    -Debug Tool: SVC Screening ON - abend when multitasking is done
     via ATTACH.
     There are different scenarios which will be fixed with this
     APAR:
      Debug Tool: ABEND in IMS application when started with
      EQANMDBG.
      Debug Tool: ABENDS0C4 when returning from subtask.
     (PI78905 at 13.1)
    
    -Program Check at EQARCL4+'11497C'x when COBOL V5 or higher
     program uses user-defined Unicode Codepage.
     (PI79945 at 13.1)
    
    -Using the Debug Tool IMS Transaction Isolation Facility, in
     some circumstances, the messages stay in the IMS input queue
     or input buffer after the debug session has been terminated.
     (PI80815 at 13.1)
    
    -Debug Tool, with the IMS Transaction Isolation Facility, can
     still remain active after a stop of the IMS sub-region.
    
     The panel "IMS Transaction Isolation Facility" shows that the
     sub-region has been stopped. In the panel "SDSF active user"
     it can be observed that the sub-region is still
     present/running.
    
     This can happen, for example, when the user makes the "stop"
     of the IMS sub-region in the TSO interface while the process /
     program is stopped on a breakpoint in the Debug Perspective
     within the RDz interface.
    
     (PI80876 at 13.1)
    
    -Debug Tool IMS Transaction Isolation Facility: Don't allow
     DEREGISTER if private MPR is still started.
    
    --- End Service ---
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Debug Tool 13.1 users who need the           *
    *                 features or have the problems described      *
    *                 in the Problem Description.                  *
    ****************************************************************
    * PROBLEM DESCRIPTION: --- Features ---                        *
    *                                                              *
    *                      -Allow store of STARTSTOP msgs in       *
    *                       STARTSTOPMSGDSN in CICS environment.   *
    *                                                              *
    *                      -Debug Tool IMS Transaction Isolation   *
    *                       Facility: Implement DFSMSCE0 exit      *
    *                       sharing.                               *
    *                                                              *
    *                      -Debug Tool IMS Transaction Isolation   *
    *                       Facility: Add LIST capability to IMS   *
    *                       Transaction Isolation Facility batch   *
    *                       interface.                             *
    *                                                              *
    *                      --- End Features ---                    *
    *                                                              *
    *                      --- Service ---                         *
    *                                                              *
    *                      -ABEND in EQA00OHC+'20D8'x when using   *
    *                       Debug Tool for COBOL V5 or V6 and      *
    *                       TEST(NOSOURCE) with SET FREQUENCY ON   *
    *                       in a preference file.                  *
    *                       (PI74365 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool Utility JCL Analyzer gets   *
    *                       EQA3058E Symbolic name too long for    *
    *                       long symbolic names and variables.     *
    *                       (PI75129 at 13.1)                      *
    *                                                              *
    *                      -Possible ABENDS0C4 in EQA00EVH when    *
    *                       running Debug Tool with LE parameter   *
    *                       TEST(ERROR,,*,*), and no Terminal      *
    *                       Interface Manager (TIM) session        *
    *                       connected.                             *
    *                       (PI74537 at 13.1)                      *
    *                                                              *
    *                      -ABENDS0C4 in EQA00KBM+'10C2'x when     *
    *                       debugging in remote debug session.     *
    *                       (PI74572 at 13.1)                      *
    *                                                              *
    *                      -Short-on-storage (SOS) in CICS when    *
    *                       debugging application with large       *
    *                       EQALANGX file.                         *
    *                       (PI75071 at 13.1)                      *
    *                                                              *
    *                      -ABEND in EQA0SXUT+'5208'x with SET     *
    *                       LIST BY SUBSCRIPT ON in remote debug   *
    *                       session.                               *
    *                       (PI75101 at 13.1)                      *
    *                                                              *
    *                      -Memory view contains ???? when it      *
    *                       should contain values.                 *
    *                       (PI75428 at 13.1)                      *
    *                                                              *
    *                      -Currently Debug Tool's exit EQAD3CXT   *
    *                       will continue to allocate the          *
    *                       EQAUOPTS DS even though no entry in    *
    *                       the XREF table was found .             *
    *                                                              *
    *                       + EQAU999I CROSS REFERENCE ENTRY NOT   *
    *                       FOUND.  TRANSACTION ID IS:  TRANS9999  *
    *                                                              *
    *                       The process should stop here so the    *
    *                       following steps are not executed       *
    *                                                              *
    *                       + EQAU999I PROFILE DATA SET NAME:      *
    *                       JOHNS.DBGTOOL.EQAUOPTS                 *
    *                       + EQAU999E DATA SET ALLOCATION         *
    *                       FAILED. DATA SET NAME IS:              *
    *                       JOHNS.DBGTOOL.EQAUOPTS                 *
    *                       + EQAU999E DYNAMIC ALLOCATION          *
    *                       RETURNED THE FOLLOWING INFORMATION:    *
    *                       + EQAU999E RETURN CODE=00000004,       *
    *                       REASON CODE=1708, INFO CODE= 0002      *
    *                                                              *
    *                       (PI76259 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool Coverage Utility annotated  *
    *                       listing for assembler truncated        *
    *                       because of misidentified MACRO/MEND    *
    *                       statement.                             *
    *                       (PI76617 at 13.1)                      *
    *                                                              *
    *                      -The input field pDsnStat in panel      *
    *                       EQAPMPSL for Debug Tool is too short   *
    *                       causing the DATASET NAME to be         *
    *                       truncated in the Debug Tool IMS        *
    *                       Transaction Isolation Facility.        *
    *                       (PI77408 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool does not show all of        *
    *                       multiple CSECTS if configuration file  *
    *                       with multiple commands is used.        *
    *                       (PI77399 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool IMS Transaction Isolation   *
    *                       Facility uses delay debug option       *
    *                       which conflicts with the EQAOPTS       *
    *                       delay debug option.                    *
    *                       (PI80811 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool fails with ABENDS0C4 in     *
    *                       EQA0SBPP+'1C3E' in remote debug        *
    *                       session start up.                      *
    *                       (PI78394 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool program check at            *
    *                       EQA00AEI+'9A6'x when run EQAWIVPB      *
    *                       sample in remote debug mode.           *
    *                       (PI78765 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool: SVC Screening ON - abend   *
    *                       when multitasking is done via ATTACH.  *
    *                       There are different scenarios which    *
    *                       will be fixed with this APAR:          *
    *                        Debug Tool: ABEND in IMS application  *
    *                        when started with EQANMDBG.           *
    *                        Debug Tool: ABENDS0C4 when returning  *
    *                        from subtask.                         *
    *                                                              *
    *                       (PI78905 at 13.1)                      *
    *                                                              *
    *                      -Program Check at EQARCL4+'11497C'x     *
    *                       when COBOL V5 or higher program uses   *
    *                       user-defined Unicode Codepage.         *
    *                       (PI79945 at 13.1)                      *
    *                                                              *
    *                      -Using the Debug Tool IMS Transaction   *
    *                       Isolation Facility, in some            *
    *                       circumstances, the messages stay in    *
    *                       the IMS input queue or input buffer    *
    *                       after the debug session has been       *
    *                       terminated.                            *
    *                       (PI80815 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool, with the IMS Transaction   *
    *                       Isolation Facility, can still remain   *
    *                       active after a stop of the IMS         *
    *                       sub-region.                            *
    *                                                              *
    *                       The panel "IMS Transaction Isolation   *
    *                       Facility" shows that the sub-region    *
    *                       has been stopped. In the panel "SDSF   *
    *                       active user" it can be observed that   *
    *                       the sub-region is still                *
    *                       present/running.                       *
    *                                                              *
    *                       This can happen, for example, when     *
    *                       the user makes the "stop" of the IMS   *
    *                       sub-region in the TSO interface while  *
    *                       the process / program is stopped on a  *
    *                       breakpoint in the Debug Perspective    *
    *                       within the RDz interface.              *
    *                                                              *
    *                       (PI80876 at 13.1)                      *
    *                                                              *
    *                      -Debug Tool IMS Transaction Isolation   *
    *                       Facility: Don't allow DEREGISTER if    *
    *                       private MPR is still started.          *
    *                                                              *
    *                      --- End Service ---                     *
    ****************************************************************
    * RECOMMENDATION: Installations that need these features or    *
    *                 problem fixes should install this service.   *
    ****************************************************************
    New features and miscellaneous service.
    

Problem conclusion

  • New feature and service available.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI75494

  • Reported component name

    DEBUG TOOL Z/OS

  • Reported component ID

    5655Q1000

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-01-26

  • Closed date

    2017-05-22

  • Last modified date

    2017-06-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • DMH000D  DMH4001D DMH4001I DMH4002I DMH4003I DMH4005I DMH4006I
    DMH4007D DMH4007I DMH4008I DMH4009I DMH4010I DMH4011I DMH4012I
    DMH4013I DMH4014I DMH4015I DMH4016I DMH4017I DMH4018I DMH4019I
    DMH4020I DMH4021I DMH4022I DMH4023I DMH4024I DMH4025I DMH4026I
    DMH4027I DMH4028I DMH4030I DMH4032I DMH4035D DMH4035I DMH4036I
    DMH4037I DMH4038I DMH4044I DMH4045I DMH4046I DMH4047I DMH4048I
    DMH4049I DMH4050D DMH4050I DMHCONST DMHDBCS  DMHIO    DMHIOAPI
    DMHLCL   DMHU001I DMHU005I DMHU900I DMHU920I DMHU921I DMHU930D
    DMHU930I DMHU940D DMHU940I DMHU941I DMHU950D DMHU950I DMHU988I
    DMHU989I DMHU990I DMHU993I DMHU994I DMHU995I DMHU996I DMHU997I
    DMHUTMSG EQA00A64 EQA00ABE EQA00AEH EQA00AEI EQA00ALO EQA00ANL
    EQA00BKP EQA00BLD EQA00BLK EQA00BND EQA00BPP EQA00CCV EQA00CCX
    EQA00CEE EQA00CEX EQA00CHG EQA00CIC EQA00CND EQA00CTX EQA00CUS
    EQA00CV  EQA00CVC EQA00CVT EQA00DBG EQA00DBH EQA00DBI EQA00DBJ
    EQA00DCL EQA00DEH EQA00DEI EQA00DLD EQA00DSF EQA00DTC EQA00DTL
    EQA00DU  EQA00EH2 EQA00EHB EQA00EHI EQA00EMG EQA00ENV EQA00EVH
    EQA00EXE EQA00FA  EQA00FIN EQA00FRE EQA00GCC EQA00GDD EQA00GDF
    EQA00GDG EQA00GDP EQA00GDV EQA00GFU EQA00GFV EQA00GIV EQA00GLV
    EQA00GPA EQA00GSV EQA00GTO EQA00HKN EQA00HKS EQA00INT EQA00KBM
    EQA00LAM EQA00LBL EQA00LCM EQA00LDD EQA00LIS EQA00LLC EQA00LLF
    EQA00LLH EQA00LLT EQA00LMS EQA00LNG EQA00LRC EQA00LSE EQA00LST
    EQA00MEM EQA00MSG EQA00NAM EQA00NML EQA00NMU EQA00NTC EQA00OEH
    EQA00OEI EQA00OHC EQA00OHH EQA00OHL EQA00OHT EQA00OHV EQA00PBK
    EQA00PDM EQA00POP EQA00PST EQA00QFY EQA00QNS EQA00QRY EQA00REG
    EQA00RES EQA00RPB EQA00RSV EQA00RUN EQA00RWD EQA00SBM EQA00SET
    EQA00STT EQA00STU EQA00SVC EQA00TRA EQA00TTL EQA00VAR EQA00XML
    EQA01SV2 EQA01SVC EQA02BLK EQA02CUS EQA02EXP EQA02LOC EQA02PFM
    EQA02PST EQA02STT EQA03ASN EQA03BLK EQA03CUS EQA03EXP EQA03PFM
    EQA03PST EQA03STT EQA04API EQA04BLK EQA04CMS EQA04CUS EQA04EXP
    EQA04PFM EQA04PST EQA04STT EQA05BLK EQA05CUS EQA05EXP EQA05PFM
    EQA05PST EQA05STT EQA07BLK EQA07CUS EQA07EXP EQA07PST EQA07STT
    EQA08BLK EQA08CUS EQA08EXP EQA08PFM EQA08PST EQA08STT EQA0AIP1
    EQA0AIP2 EQA0AIPD EQA0CINF EQA0OIP2 EQA0S0YC EQA0S0YE EQA0S4CN
    EQA0S4DS EQA0S4LB EQA0S4YC EQA0S4YE EQA0S9LB EQA0S9YC EQA0S9YE
    EQA0SBKP EQA0SBLD EQA0SBPP EQA0SCBP EQA0SCHG EQA0SCL1 EQA0SCL2
    EQA0SCLU EQA0SCMD EQA0SCPU EQA0SDBI EQA0SDLD EQA0SDTC EQA0SDTL
    EQA0SDU  EQA0SEMC EQA0SEXA EQA0SEXE EQA0SEXN EQA0SEXP EQA0SEXU
    EQA0SEXX EQA0SINP EQA0SLCM EQA0SLDD EQA0SLSE EQA0SMSU EQA0SNAM
    EQA0SNTC EQA0SPRD EQA0SQFY EQA0SRGU EQA0SRP1 EQA0SRP2 EQA0SRP3
    EQA0SRP4 EQA0SRPC EQA0SRQ1 EQA0SRQ2 EQA0SRQ3 EQA0SRQ4 EQA0SRSM
    EQA0STKH EQA0STRE EQA0SUT1 EQA0SUT2 EQA0SUTI EQA0SXR1 EQA0SXRI
    EQA0SXU1 EQA0SXUT EQA0XCUS EQA0YCUS EQA10AFS EQA10AKA EQA10ALO
    EQA10ANL EQA10ASN EQA10BKC EQA10BKD EQA10BKE EQA10BKL EQA10BKP
    EQA10BKS EQA10BKT EQA10BLK EQA10BNK EQA10BPP EQA10BPQ EQA10BPR
    EQA10CCV EQA10CMD EQA10CND EQA10CUS EQA10CV  EQA10CVC EQA10DAT
    EQA10DDT EQA10DES EQA10DMM EQA10DPA EQA10DSE EQA10DTC EQA10DTL
    EQA10EMC EQA10EXE EQA10EXM EQA10EXN EQA10EXX EQA10FBP EQA10FCI
    EQA10FIN EQA10FLO EQA10FND EQA10GTO EQA10HAD EQA10HLS EQA10HRS
    EQA10INP EQA10INT EQA10IPD EQA10LAM EQA10LCM EQA10LDD EQA10LIN
    EQA10LIT EQA10LNK EQA10LOG EQA10LSE EQA10LST EQA10MEM EQA10MGF
    EQA10MON EQA10MVO EQA10MVS EQA10NAM EQA10NRM EQA10OUT EQA10PBK
    EQA10PDM EQA10PRC EQA10PRD EQA10PTP EQA10QFY EQA10QNS EQA10QRY
    EQA10QRZ EQA10RET EQA10RST EQA10SET EQA10SEV EQA10SID EQA10STM
    EQA10STU EQA10SVC EQA10SYC EQA10SYE EQA10TGA EQA10TOG EQA10TRA
    EQA10VAR EQA10VAT EQA10XML EQA12CED EQA12CEI EQA12CES EQA12CEX
    EQA12CUR EQA12DCL EQA12DSP EQA12LX1 EQA12LXB EQA12QNS EQA12SCN
    EQA12SYC EQA12SYE EQA13CEX EQA13CUR EQA13DCL EQA13DSP EQA13LX1
    EQA13LXB EQA13MDV EQA13QNS EQA13SCN EQA13SWC EQA13SYC EQA13SYE
    EQA14CAL EQA14CEX EQA14CMS EQA14CUR EQA14DCL EQA14DSP EQA14EVL
    EQA14LX1 EQA14LXB EQA14MDV EQA14PRF EQA14QNS EQA14SCN EQA14SYC
    EQA14SYE EQA17CED EQA17CEI EQA17CEX EQA17CUR EQA17DCL EQA17DSP
    EQA17LX1 EQA17LXB EQA17QNS EQA17SCN EQA17SYC EQA17SYE EQA18CED
    EQA18CEI EQA18CEX EQA18CUR EQA18DCL EQA18DSP EQA18LX1 EQA18LXB
    EQA18QNS EQA18SCN EQA18SYC EQA18SYE EQA1S4LB EQA1S9LB EQA30DMM
    EQA30DU  EQA30HSH EQA30INT EQA30KBM EQA30LNK EQA30NTC EQA30PST
    EQA30PT  EQA30SBM EQA30SRT EQA30STO EQA30STR EQA30TK  EQA30TKI
    EQA50COL EQA50CTL EQA50FC1 EQA50FC2 EQA50IMW EQA50INP EQA50LIS
    EQA50PRE EQA50PRO EQA50REQ EQA50SRV EQA50TMN EQA50VIO EQA50WIN
    EQA80CUS EQA80DPC EQA80DPI EQA80LCM EQA80STD EQA80SVC EQA80VER
    EQAAFSPS EQACCDRV EQACMDRV EQACSEXE EQACSINT EQACURPA EQAD3CSR
    EQAD3UT1 EQAD3XXT EQADCCN0 EQADCCXR EQADCMGR EQADCREP EQADCTSQ
    EQADCVSA EQADFHNO EQAEV006 EQALMA   EQANBSWT EQANCABE EQANCDBG
    EQANCFRM EQANCHAB EQANCLDE EQANCREL EQANIAFE EQANICRT EQANICTL
    EQANIPSB EQANISET EQANMDBG EQANMPOP EQAPMPSL EQARCCDA EQARCDBG
    EQARCEXP EQARCHEX EQARCI3E EQARCL4  EQARCOBD EQARCPDC EQARCTRC
    EQARCVND EQASUER0 EQASUER1 EQASUJCL EQATIEDT EQATIEXT EQAXFOR
    EQAXMSGT EQAXTIMS EQAYBCNM EQAYBGID EQAYFGID EQAYLIST EQAYSMMN
    

Fix information

  • Fixed component name

    DEBUG TOOL Z/OS

  • Fixed component ID

    5655Q1000

Applicable component levels

  • RD10 PSY UI47449

       UP17/05/24 P F705 ¢

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTQWA","label":"IBM Debug for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 October 2020