  • Closed as program error.

Error description

  • mod_zos_cmds incorrectly reports the number of lingering close
    connections as zero. This is because mod_zos_cmds counts the
    number of threads in the lingering close state instead of
    counting the number of connections.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  Users of IBM HTTP Server (powered by        *
    *                  Apache) on z/OS.                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: mod_zos_cmds incorrectly reports the    *
    *                      number of lingering close connections   *
    *                      as zero.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    mod_zos_cmds incorrectly reports the number of lingering close
    connections as zero. This is because the lingering close state
    is a state of a connection and not a thread, but the number of
    threads in the lingering close state are counted. Instead,
    the number of connections in the lingering close state should
    be counted.
    

Problem conclusion

  • mod_zos_cmds was updated to report the number of connections
    in the lingering close state instead of the number of threads.
    
    This fix is targeted for IBM HTTP Server fix packs:
     - 9.0.0.4
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI73951

  • Reported component name

    WAS IHS ZOS

  • Reported component ID

    5655I3510

  • Reported release

    90P

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-12-19

  • Closed date

    2016-12-20

  • Last modified date

    2017-01-09

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    WAS IHS ZOS

  • Fixed component ID

    5655I3510

Applicable component levels

  • R90P PSY