A fix is available
APAR status
Closed as program error.
Error description
EXEC CICS ASKTIME ABSTIME may return a value where the number of millisecond units is less than the value returned by another request executed just before it.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All CICS users. * **************************************************************** * PROBLEM DESCRIPTION: The number of milliseconds returned * * by EXEC CICS ASKTIME ABSTIME may be * * lower than the actual value in some * * cases. * **************************************************************** EXEC CICS ASKTIME ABSTIME returns the time in units of milliseconds and not 1/100s of a second. Depending on the time at which the command is actioned by CICS, there may be a rounding error which causes the millisecond digit to be lower than it should be.
Problem conclusion
DFHEIDTI has been corrected to ensure that the number of milliseconds returned by ASKTIME ABSTIME is always correct.
Temporary fix
Comments
APAR Information
APAR number
PI71972
Reported component name
CICSTS FOR ZVSE
Reported component ID
5655VSE00
Reported release
B2P
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-11-08
Closed date
2017-03-30
Last modified date
2020-02-27
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI46024
Modules/Macros
DFHEIDTI
Fix information
Fixed component name
CICSTS FOR ZVSE
Fixed component ID
5655VSE00
Applicable component levels
RB2P PSY UI46024
UP20/02/27 I 1000
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSGMGV","label":"CICS Transaction Server"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG32M","label":"APARs - VSE\/ESA environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"2.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date: