A fix is available
APAR status
Closed as program error.
Error description
When running TCP simulations that have more than 25 path statements or repeat more than 25 times a S0C4 reason code 10 or 11 is possible.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All WSim users. * **************************************************************** * PROBLEM DESCRIPTION: WSim TCP enhancements corrected. * * Previously PTF UI34087.This PTF * * replaces UI34087; * **************************************************************** * RECOMMENDATION: * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * * **************************************************************** The following enhancements are added to Workload Simulator: - Allows the user to start and stop a TCP/IP data trace specific to a client IP address and to a server port. This function can be accessed thru the WSim/ISPF interface panel option 4.1, thru the WSim Test Manager ISPF interface panel 'Add New Testcase' option 7, or by invoking the WSim tracing facility, ITPIPTRX, using JCL.To perform this function, WSim uses the z/OS Communication Server real-time application-controlled TCP/IP trace Network Management Interface (NMI). - Provides function to format data trace records utilizing the z/OS Communication Server trace record formatting NMI. This function can be accessed thru the WSim/ISPF interface panel option 4.2, or by invoking the WSim utility program, ITPIPFMT, using JCL. - Provides function to process TCP/IP HTTP packet and data trace records saved in a data set to generate Structured Translator Language (STL). This function can be accessed thru the WSim/ISPF interface panel option 5.4, thru the WSim Test Manager ISPF interface panel Add New Testcase option 8, or by invoking the WSim STL generating facility, ITPIPGEN, using JCL. - For a client coded in a TCP/IP network definition, allows the user to specify, with the PATH= operand, the number of times a path defined in a PATH statement will be executed during a simulation. Requirements: - Workload Simulator 1.1 - z/OS 2.1 to utilize the z/OS Communication Server real-time application-controlled TCP/IP trace Network Management Interface (NMI) - To use the TCP/IP Trace Utility a user must have READ access to the following SAF resource profiles in the SERVAUTH class: * EZB.TRCCTL.sysname.tcpname.OPEN * EZB.TRCCTL.sysname.tcpname.DATTRACE where: * sysname is the MVS system name where the TCP/IP stack is running * tcpname is the TCP/IP stack job name - To use the TCP/IP Trace Utility to obtain a trace in clear text for a server using AT-TLS for message encryption the user will require READ access to the following SAF resource profile in the SERVAUTH class: * EZB.TRCSEC.sysname.tcpname.ATTLS Note: When simulating TCP/IP clients, WSim does not have support for establishing a secure connection using SSL. Therefore when using WSim to simulate a client that requires a secure connection you will need to define a TCP/IP networking policy to ensure the simulated client uses AT-TLS. For further information on the SAF resources refer to the z/OS Communications Server IP Programmer's Guide and Reference. For further information on TCP/IP networking policies refer to the z/OS Communications Server IP Configuration Guide and the z/OS Communications Server IP Configuration Reference. Updates to Workload Simulator manuals are available: - Utilities Guide SC31-8947-01 - Users Guide SC31-8948-01 - Creating WSim Scripts SC31-8945-01 - Script Guide and Reference SC31-8946-01 - Test Manager Users Guide and Reference SC31-8949-01 - Messages and Codes SC31-8951-01 http://www.ibm.com/support/knowledgecenter/SSL28L_1.1.0 http://www.ibm.com/software/awdtools/workloadsimulator/library/ +-------------------------------------------------------------+ + Please check our Communications Server for OS/390 homepages + + for common networking tips and fixes. The URL for these + + homepages can be found in Informational APAR II11334. + +-------------------------------------------------------------+ New functions have been added.
Problem conclusion
This PTF repairs prev PTF UI34087 If the ITERATE functionality that was introduced in that PTF is used there is a permanent restriction that there must be no more than 25 PATH statements in a message generation deck. Like wise there can be no more than 25 repeats. * Cross Reference between External and Internal Names SPA_NAME (IDSS_NAM)
Temporary fix
Comments
×**** PE18/03/02 PTF IN ERROR. SEE APAR PI93998 FOR DESCRIPTION
APAR Information
APAR number
PI63016
Reported component name
IBM WORKLOAD SI
Reported component ID
5655I3900
Reported release
110
Status
CLOSED PER
PE
YesPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-05-24
Closed date
2016-11-08
Last modified date
2018-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI42363
Modules/Macros
H281110J ITMEC ITMECA ITMES ITMESN ITMEZ ITMEZCI ITMEZG ITMEZM ITMEZMS ITMEZY ITMPC ITMPCAA ITMPCAAH ITMPCAC ITMPCACH ITMPCAM8 ITMPCAM9 ITMPCAN8 ITMPCAN9 ITMPCH ITMPCM8H ITMPCM9H ITMPC2 ITMPS ITMPSH ITMPSN1 ITMPSN1H ITMPSN3 ITMPSN3H ITMPUTL ITMPUTLH ITMPUTL1 ITMPUT1H ITMPZG ITMPZGH ITMPZTC1 ITMPZY ITMPZYH ITMSCTSG ITM0PRIE ITM05 ITM07 ITPCONV ITPDDDEF ITPDTCMN ITPFE09 ITPFE16 ITPFE17 ITPFE18 ITPFE20 ITPFE21 ITPFE23 ITPIPFMT ITPIPGEN ITPIPGRC ITPIPGST ITPIPMSG ITPIPPRT ITPIPSTL ITPIPSTM ITPIPTRC ITPIPTRX ITPIPV6V ITPKSCAN ITPLBBLD ITPLGDSQ ITPLUS99 ITPMSTRC ITPPUT ITPRCIFR ITPRSQIO ITPSCAN ITPSELPT ITPWTO ITPYAEND ITP0GENP ITP0HCOM ITP0HI01 ITP0HI02 ITP0HI03 ITP0HI04 ITP0HI05 ITP0HI08 ITP0HI09 ITP0HI10 ITP0HI13 ITP0HI14 ITP0HNDX ITP0HTCF ITP0HTCG ITP0HTCM ITP0HTCS ITP0HTCT ITP0H001 ITP0H002 ITP0H031 ITP0H079 ITP0H200 ITP0H201 ITP0H202 ITP0H203 ITP0H204 ITP0H212 ITP0H213 ITP0H214 ITP0H215 ITP0PRIE ITP0PRIP ITP0TCFP ITP0TCFS ITP0TCGP ITP0TCGS ITP0TCMP ITP0TCPS ITP0TCSP ITP0TCTP
Fix information
Fixed component name
IBM WORKLOAD SI
Fixed component ID
5655I3900
Applicable component levels
R110 PSY UI42363
UP16/11/11 P F611 Ø
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSL28L","label":"Workload Simulator for z\/OS and OS\/390"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"110","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: