IBM Support

PI62901: ABEND U3999 WITH MESSAGE: EQQ0000T MODULE: EQQBSFS , REASON: STOROVLY SEEN AFTER REMOVING FTAS FROM THE TOPOLOGY

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • An abend U3999 is seen after removing FTAs from the TOPOLOGY.
    Dump symptoms are:
     USER COMPLETION CODE=3999
        PSW AT TIME OF ERROR  078D1000   8002A1D4  ILC 2  INTC 0D
        ACTIVE LOAD MODULE           ADDRESS=00019000
    OFFSET=000111D4
        NAME=EQQBEX
        DATA AT PSW  0002A1CE - 00181610  0A0D1812  0A0D47F0
        GR 0: 80000000   1: 80000F9F
          2: 00000F9F   3: 000065A8
          4: C5D8D8C2   5: C4C54040
          6: C5E7C9E3   7: 40404040
          8: 00000F9F   9: 00000001
          A: 0002DCD0   B: 80029FC0
          C: 12600040   D: 00006DC8
          E: 8001B8DA   F: 00000000
     END OF SYMPTOM DUMP
    .
    The abend is reproducible in the following way:
    - defining work stations
    - defining applications that refer these work stations
    - deleting some (more than 12) ws but we do not change the
      the applications that refer them.
    - running an LTP create
    .
    The correct procedur for removing FTAs from the TOPOLOGY
    however (as documented in technote 1156448 is:
    After all references to the old workstation have been removed
    from the AD
    database, the LTP, and the CP, then remove the workstation from
    the AD, and
    from the TOPOLOGY. It will then be deleted from the TWSz ISPF
    dialogs by the
    next CP EXTEND/REPLAN batch job.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All TWS for zos users.                       *
    *                 All IWS for zos users.                       *
    *                 FUNCTION=LTP                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: When some work stations are deleted     *
    *                      without modifying the applications      *
    *                      that refer them, an abend U3999, with   *
    *                      REASON:STOROVLY, could occur running    *
    *                      the LTP.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    An LTP batch job could end with abend U3999 and REASON:STOROVLY
    when it runs after some work stations are deleted without
    modifying the applications that refer them.
    

Problem conclusion

  • The length of the DURATION area was too small,
    now it is increased.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI62901

  • Reported component name

    TIV WRKLD SCHD

  • Reported component ID

    5697WSZ01

  • Reported release

    602

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-23

  • Closed date

    2016-07-21

  • Last modified date

    2017-01-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI39531 UI39532 UI39533 UI39534 UI39535

Modules/Macros

  •    EQQLCMGE
    

Fix information

  • Fixed component name

    TIV WRKLD SCHD

  • Fixed component ID

    5697WSZ01

Applicable component levels

  • R512 PSY UI39531

       UP16/12/07 P F612

  • R602 PSY UI39532

       UP16/12/07 P F612

  • R912 PSY UI39533

       UP16/12/07 P F612

  • R922 PSY UI39534

       UP16/12/07 P F612

  • R932 PSY UI39535

       UP16/12/07 P F612

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSRULV","label":"IBM Workload Scheduler for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"602","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"602","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information