Direct links to fixes
readme.htm
RAAzInstallRepository
RAAzInstall
RAAInstallRepository
RAAInstall
Rational Asset Analyzer Fix Pack 10 (6.1.0.10) for 6.1
Rational Asset Analyzer for System z Fix Pack 10 (6.1.0.10) for 6.1
Rational Asset Analyzer Fix Pack 11 (6.1.0.11) for 6.1
Rational Asset Analyzer for System z Fix Pack 11 (6.1.0.11) for 6.1
Rational Asset Analyzer Fix Pack 12 (6.1.0.12) for 6.1
Rational Asset Analyzer for System z Fix Pack 12 (6.1.0.12) for 6.1
Rational Asset Analyzer Fix Pack 13 (6.1.0.13) for 6.1
Rational Asset Analyzer for System z Fix Pack 13 (6.1.0.13) for 6.1
Rational Asset Analyzer Fix Pack 14 (6.1.0.14) for 6.1
Rational Asset Analyzer for System z Fix Pack 14 (6.1.0.14) for 6.1
Rational Asset Analyzer Fix Pack 15 (6.1.0.15) for 6.1
Rational Asset Analyzer for System z Fix Pack 15 (6.1.0.15) for 6.1
Rational Asset Analyzer Fix Pack 16 (6.1.0.16) for 6.1
Rational Asset Analyzer for System z Fix Pack 16 (6.1.0.16) for 6.1
Rational Asset Analyzer for System z Fix Pack 17 (6.1.0.17) for 6.1
Rational Asset Analyzer Fix Pack 17 (6.1.0.17) for 6.1
Rational Asset Analyzer Fix Pack 18 (6.1.0.18) for 6.1
Rational Asset Analyzer for System z Fix Pack 18 (6.1.0.18) for 6.1
Rational Asset Analyzer Fix Pack 19 (6.1.0.19) for 6.1
Rational Asset Analyzer for System z Fix Pack 19 (6.1.0.19) for 6.1
Rational Asset Analyzer Fix Pack 20 (6.1.0.20) for 6.1
Rational Asset Analyzer for System z Fix Pack 20 (6.1.0.20) for 6.1
Rational Asset Analyzer for System z Fix Pack 21 (6.1.0.21) for 6.1
Rational Asset Analyzer Fix Pack 21 (6.1.0.21) for 6.1
Rational Asset Analyzer Fix Pack 22 (6.1.0.22) for 6.1
Rational Asset Analyzer for System z Fix Pack 22 (6.1.0.22) for 6.1
Rational Asset Analyzer for System z Fix Pack 23 (6.1.0.23) for 6.1
Rational Asset Analyzer Fix Pack 23 (6.1.0.23) for 6.1
APAR status
Closed as program error.
Error description
For some PL/I source, when scanned, two transfers of control were detected by RAA. For the second control transfer, the parameters passed are correctly displayed on the Control Transfers tab of the Program Details page. The first control transfer call, however, does not show any parameters even though the source shows one.
Local fix
none known
Problem summary
External Entry References were not being tagged as Control transfers (CNX) and no CNX record was created on the export file. Also, a new record type (0x3C) was added to Enterprise PL/I for z/OS V4.R5.M0.
Problem conclusion
Code was changed so that the External Entry References are now being correctly identified as Control Transfers and the CNX record is now created on the export file. Also, support for the new record type was added to the CBS scanner.
Temporary fix
Comments
APAR Information
APAR number
PI57337
Reported component name
RAA FOR SSTEM Z
Reported component ID
5655W5700
Reported release
610
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-02-16
Closed date
2016-02-17
Last modified date
2016-02-18
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
scanner
Fix information
Fixed component name
RAA FOR SSTEM Z
Fixed component ID
5655W5700
Applicable component levels
R610 PSY
UP
Document Information
Modified date:
17 October 2021