IBM Support

PI45636: RECEIVE MESSAGE FMNIA059 WHEN ATTEMPTING TO EDIT AN IMS DATABASE USING FILE MANAGER/IMS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When attempting to edit an IMS database using a static PSB,
    with PROCOPT=A on all segments except for one segment with
    PROCOPT=I, receive the following message:
     PCB for database xxxxxxxx has PROCOPT=A; the function cannot
    be performed with these processing options.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: FM/IMS users accessing databases via static  *
    *                 PSBs.                                        *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. FM/IMS function using a static PSB   *
    *                      issues error message FMNIA059 "PCB for  *
    *                      database dbname has PROCOPT=xxxx; the   *
    *                      function cannot be performed with these *
    *                      processing options." when the function  *
    *                      can be performed with these options.    *
    *                      2. FM/IMS function using a static PSB   *
    *                      to access a DEDB database issues error  *
    *                      message FMNIA015 "IMS read failed - An  *
    *                      attempt to read an IMS segment has      *
    *                      failed. The function has been           *
    *                      terminated." occurring when the PROCOPT *
    *                      of the specified PCB includes the P     *
    *                      option.                                 *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    1. The problem occurs when one or more of the SENSEG statements
    within the specified PCB have a PROCOPT of I or K.
    2. The problem occurs because IMS issues the GC status code when
    an attempt is made to cross a unit-of-work boundary.
    

Problem conclusion

  • 1. FM/IMS has been modified to:
    - handle PCBs with PROCOPT=I SENSEG statements.
    - issue error message FMNIB567 when the PCB has PROCOPT=K SENSEG
    statements.
    2. FM/IMS has been modified to reissue the DL/I call when the
    call receives a GC status code.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI45636

  • Reported component name

    FILE MANAGER Z/

  • Reported component ID

    5655Q1200

  • Reported release

    D10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-07-24

  • Closed date

    2016-03-02

  • Last modified date

    2016-04-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  •    FMN0LVL  FMN1LVL  FMN1LVLJ FMN1LVLK
    

Fix information

  • Fixed component name

    FILE MANAGER Z/

  • Fixed component ID

    5655Q1200

Applicable component levels

  • RD1C PSY UI35832

       UP16/03/10 P F603

  • RD10 PSY UI35829

       UP16/03/10 P F603

  • RD14 PSY UI35836

       UP16/03/10 P F603

  • RD15 PSY UI35837

       UP16/03/10 P F603

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAV","label":"File Manager for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
05 April 2016