Direct links to fixes
5.3.0-TIV-KD5-FP0009.zip
5.3.0-TIV-KD5-FP0009.tar.gz
5.3.0-TIV-KD5-FP0009.README
5.3.0-TIV-KD5-FP0008.zip
5.3.0-TIV-KD5-FP0008.tar.gz
5.3.0-TIV-KD5-FP0008.README
5.3.0-TIV-KD5-FP0007.zip
5.3.0-TIV-KD5-FP0007.tar.gz
5.3.0-TIV-KD5-FP0007.README
5.3.0-TIV-KD5-FP0005.zip
5.3.0-TIV-KD5-FP0005.tar.gz
5.3.0-TIV-KD5-FP0005.README
5.3.0-TIV-KD5-FP0004.zip
5.3.0-TIV-KD5-FP0004.tar.gz
5.3.0-TIV-KD5-FP0004.README
5.3.0-TIV-KD5-FP0001.zip
5.3.0-TIV-KD5-FP0001.tar.gz
5.3.0-TIV-KD5-FP0001.README
Tivoli OMEGAMON XE for DB2 on z/OS
Tivoli OMEGAMON XE for DB2 on z/OS 5.3.0-TIV-KD5-FP0007
Tivoli OMEGAMON XE for DB2 on z/OS 5.3.0-TIV-KD5-FP0008
APAR status
Closed as program error.
Error description
E3270, KDPTHDD2: port number wrong '-0029216'
Local fix
n/a
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - TEMA / TEMS * * - Enhanced 3270 UI * **************************************************************** * PROBLEM DESCRIPTION: Negative port number on panel KDPTHDD2 * * in Enhanced 3270 UI and for * * Distributed Thread Detail workspace * * in TEP. * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** PROBLEM SUMMARY: Port number was erroneously treated as signed value which caused displaying ports larger than 32767 as negative values. PROBLEM CONCLUSION: Correct logic to display port number as unsigned value. KEYWORDS: NEGATIVE PORT KDPTHDD2 ENHANCED 3270 UI DISTRIBUTED THREAD DETAIL TEP
Problem conclusion
Correct logic to display port number as unsigned value.
Temporary fix
Comments
APAR Information
APAR number
PI42097
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
530
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-01
Closed date
2015-09-16
Last modified date
2017-02-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI31209 UI31210
Modules/Macros
KDPTHD1X KDPTHRDD
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
Document Information
Modified date:
10 January 2022