A fix is available
APAR status
Closed as program error.
Error description
V5.1.1 compile gives error: IGYCB7104-U Internal error while compiling function xxxxxxxx. Failed assertion on s390/MemoryReference.cpp:230. Compilation terminated. The compiler returns error under optimization values, OPT(1/2).
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: Users of Enterprise COBOL 5.1 compiling * * programs that move a DISPLAY data item to a * * COMP-3 data item in a table, using the * * DISPLAY data item as the subscript. * * * **************************************************************** * PROBLEM DESCRIPTION: Compiler abort with message * * MSGIGYIN5125-U The compilation was * * terminated due to a compiler error in * * phase id: "IGYCINIT". * * * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * * * **************************************************************** The compiler was incorrectly calculating some internal state when encountering COBOL code that moves a DISPLAY data item to a COMP-3 data item in a table, using the DISPLAY data item as the subscript, and was terminating since the state wasn't as it should have been.
Problem conclusion
The compiler was fixed to no longer abort when encountering COBOL code that moves a DISPLAY data item to a COMP-3 data item in a table, using the DISPLAY data item as the subscript
Temporary fix
Comments
APAR Information
APAR number
PI20469
Reported component name
ENT COBOL FOR Z
Reported component ID
5655W3200
Reported release
510
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-06-19
Closed date
2014-07-22
Last modified date
2014-08-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
IGYCBE
Fix information
Fixed component name
ENT COBOL FOR Z
Fixed component ID
5655W3200
Applicable component levels
R510 PSY UI19849
UP14/07/25 P F407
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.1","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
04 August 2014