A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 13 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. 0C4 in GetStgMem when processing * * PL/I AUTO/STATIC storage. * * APAR PI23641 * * 02. S201 abend in IDISLEEP. * * APAR PI23642 * * 03. S0C4 when using Fault Analyzer * * XEIIN GLUE. * * APAR PI23643 * * 04. Abend S0C4 at entry point CFREE * * when exiting interactive reanalysis * * of fault entry. * * APAR PI22236 * * 05. When formatting COBOL/5 Associated * * Storage Areas, variable * * declarations appear as * * 'IDENTIFICATION DIVISION' or some * * other inappropriate value. * * APAR PI21123 * * 06. SSIB storage not being FREEMAINed. * * APAR PI23644 * * 07. ISPF dialog error when specifying * * two or more adjacent asterisks in * * the Fault Entry List display * * history file name field. * * APAR PI21479 * * 08. IDI0144E IDIS error 0C4 when high * * activity. * * APAR PI23645 * * 09. IDI0005S IDIUTIL:524 Storage * * allocation for 88 (X'58') bytes * * failed - processing terminated. * * APAR PI23646 * * 10. Use of Fault Analyzer XEIIN exit * * can cause short on storage * * conditions. * * APAR PI23407 * * 11. IDI0144E IDIS error detected at * * IDIXDCAP:371: TCB 8B0738 S0CA * * APAR PI23647 * * 12. After access to a fault entry has * * been attempted, but rejected by the * * IDIXFXIT exit, subsequent attempts * * to access other fault entries are * * incorrectly rejected. * * APAR PI23869 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. AUTO/STATIC storage not checked for accessibility. 02. An invalid ECB reference was being used, leading to S201 abend. 03. The FA XEIIN code was not correctly allowing for a failed GETMAIN due to CICS being SOS. 04. A control block was attempted free'd, which had already been free'd. 05. DWARF does not have a decl_line attribute for internally generated variables (eg. SQL---PLIST). 06. The check for an IDIOFF DD, or a DD as specified in the AdditionalIDIOffDD option, causes an IDIS subsystem call. Due to incorrect register usage, the SSIB storage area was not being FREEMAINed. 07. The specified history file name was not adequately checked for valid syntax before calling the ISPF LMDINIT service. 08. Fault Analyzer IDIS subsystem message IDI0144E 0C4 abend after Coupling Facility XCF message delays. 09. A loop occurred due to the absence of a SYSIN DD statement. 10. Storage areas GETMAINed by XEIIN code were not being explictly FREEMAINed, which for long running tasks could lead to short on storage conditions. 11. Fault Analyzer IDIS subsystem message IDI0144E followed by IDI0145I IDIS subtask for: IDISCJST terminated. Requesting regions may then hang until the IDIS subsystem is stopped and restarted. 12. The rejected access was incorrectly being remembered for other fault entries, for which access should have been granted.
Problem conclusion
01. AUTO/STATIC storage now checked for accessibility. 02. The invalid reference has been removed. 03. A failed GETMAIN is now correctly handled. 04. The problem has been corrected. 05. Declared line # set to 1, which indicates an internally generated variable. 06. The incorrect register usage has been fixed so the SSIB will now be correctly FREEMAINed. 07. The history file name syntax checking has been improved to prevent the problem. 08. The XCF recovery code has been updated to ensure delayed messages are still valid to process. 09. A SYSIN DD statement is no longer required when all control statements are passed to IDIUTIL via the PARM field. 10. All storage areas are correctly FREEMAINed. 11. Code added to insure the IDISCJST termination cause IDIS to terminate. 12. The access to individual fault entries is now being determined correctly.
Temporary fix
Comments
APAR Information
APAR number
PI19883
Reported component name
FAULT ANALYZER
Reported component ID
5655Q1100
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-06-12
Closed date
2014-08-15
Last modified date
2014-09-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI20632
Modules/Macros
HADQD10J IDICAASM IDICABND IDICALE IDICALOC IDICASUB IDICCFND IDICISA IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICSMF IDICSVCR IDICSV11 IDICUXCS IDICUXWR IDIDA IDIDASUB IDIDATST IDIGMAIN IDIHPMSG IDIMCICS IDINDEX IDIPDDIR IDIPDSCU IDIPH239 IDIS$NDX IDISAMAN IDISAQUE IDISASUB IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJAX IDISJLD IDISJLOG IDISLEEP IDISLKUP IDISLOG IDISMAIN IDISREG IDISRFRA IDISRFRD IDISTIME IDISUPDI IDISVIEW IDISXPLA IDISXPLB IDISXPLC IDISXPLP IDIUGPDF IDIUTIL IDIXAFMT IDIXALOG IDIXASUB IDIXCCEE IDIXCC52 IDIXCEE IDIXCE53 IDIXCE67 IDIXCE68 IDIXCE69 IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCX52 IDIXCX53 IDIXDCAP IDIXDSAC IDIXDUMP IDIXFA IDIXGSPC IDIXGSPS IDIXLFMT IDIXMAP IDIXOPT IDIXSNAP IDIXTSEL IDIXUFMA IDIXUFMC IDIXUFMH
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655Q1100
Applicable component levels
RD10 PSY UI20632
UP14/08/25 P F408
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
03 September 2014