IBM Support

PI17013: MISCELLANEOUS BUG FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 12 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Fault Analyzer event list info for  *
    *                          NORENT assembler not useful.        *
    *                          APAR PI19146                        *
    *                      02. The application's last CICS 3270    *
    *                          buffer is not being formatted       *
    *                          correctly.                          *
    *                          APAR PI15843                        *
    *                      03. Abend S0C4 in PliSepStruct when     *
    *                          processing constants in SYSDEBUG    *
    *                          side file.                          *
    *                          APAR PI16631                        *
    *                      04. Intermittent problem leads to abend *
    *                          S0C4 during execution of Formatting *
    *                          user exit.                          *
    *                          APAR PI17241                        *
    *                      05. User is performing CICS SDUMP       *
    *                          analysis and looking at the CQ      *
    *                          Domain. Values in the panels are    *
    *                          incorrect.                          *
    *                          APAR PI15010                        *
    *                      06. Fault Analyzer ErrorHandler option  *
    *                          names might not get honoured if     *
    *                          input from an MVS dump.             *
    *                          APAR PI19150                        *
    *                      07. Fault Analyzer interactive analysis *
    *                          Listing/Side File Mismatch panel    *
    *                          ENTER action for COBOL does not     *
    *                          force use of the side file.         *
    *                          APAR PI19166                        *
    *                      08. Reported assembler DSECT has        *
    *                          missing fields.                     *
    *                          APAR PI17568                        *
    *                      09. CICS Container data incorrectly     *
    *                          being displayed in ASCII rather     *
    *                          than EBCDIC.                        *
    *                          APAR PI19167                        *
    *                      10. FA formats too many CICS trace      *
    *                          entries.                            *
    *                          APAR PI18082                        *
    *                      11. Abend S0C4 in CobCdaSym() when      *
    *                          processing DWARF in COBOL/5 load    *
    *                          module.                             *
    *                          APAR PI19168                        *
    *                      12. Message IDI0089I Subsystem IDISLOG  *
    *                          RC=8 Rsn=63 IDI0159I SDUMP usage    *
    *                          error.                              *
    *                          APAR PI19151                        *
    *                      13. Fault Analyzer message IDI0151W for *
    *                          a partial SVC dump not correct.     *
    *                          APAR PI18986                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. NORENT programs with DSAs imbedded in the CSECT, and often
        using non-standard linkage, are getting no event
        information.
    02. The user has a 3270 emulator which, when given a 'F2' or
        "Read Buffer" command, returns a data stream which contains
        SBA orders. FA did not have code to handle those SBAs.
    03. Constants have a structure parent which can cause them to be
        processed as structure members.
    04. Fault Analyzer is not correctly handling the abend, which
        might be expected during normal processing.
    05. Fault Analyzer is using incorrect control block offsets to
        obtain the values.
    06. When an MVS dump is used as input to Fault Analyzer to get
        a fault report on the dump, the ErrorHandler program names
        might not get recognized correctly because MVS dump input
        does not trigger FA Binder mapping of modules.
    07. The pop-up panel reporting Listing/Side File Mismatch
        indicates ENTER will accept a current COBOL SYSDEBUG file,
        but it is ignored and no source for that program is
        presented.
    08. DSECT has more fields than can be contained in single LANGX
        structure record, but only the first LANGX record is
        processed.
    09. The count of ASCII and EBCDIC characters was incorrect.
    10. FA processes all the trace entries in a particular trace
        block.
    11. Storage re-allocation did not reset pointer into area.
    12. Fault Analyzer RFR recovery after IDI0005 storage shortage
        can get IDI0089I Subsystem IDISLOG RC=8 Rsn=63 SDUMP usage
        error attempting to do a second SDUMP.
    13. The return and reason code processing for SDUMP is not
        always correctly reported when issued from IBM Fault
        Analyzer.
    

Problem conclusion

  • 01. Code added to detect the static DSA and at least show load
        module and CSECT data in the event list.
    02. Fault Analyzer has been altered to handle SBA orders in the
        Read Buffer data stream.
    03. Constants no longer processed as structure members.
    04. Fault Analyzer is now handling the abend.
    05. Fault Analyzer has been updated to use the correct offsets.
    06. The ErrorHandler code will also check entry point name, if
        program name has not been determined for an event.
    07. The code has been updated to accept the side file when
        possible.
    08. Multiple LANGX structure records now processed for large
        assembler DSECTs.
    09. The count of ASCII and EBCDIC characters has been corrected.
    10. FA is changed to stop formatting once the current timestamp
        is less than the previous timestamp.
    11. Symbol lookup pointer reset when storage area re-allocated.
    12. The logic is corrected to determine if the RFR dump has
        already been taken.
    13. Reason code processing corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI17013

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W6900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-04-29

  • Closed date

    2014-06-06

  • Last modified date

    2014-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI18643

Modules/Macros

  • IDICASUB IDICCFND IDICOPYR IDICSV11 IDIDA    IDIDASUB IDIDATST
    IDIGMAIN IDIHIBMI IDIHPMSG IDIMCICS IDINDEX  IDIPDDIR IDIPDSCU
    IDIPLT   IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJLD
    IDISJLOG IDISLKUP IDISLOG  IDISMAIN IDISREG  IDISSREQ IDISTIME
    IDISUPDI IDISVIEW IDIUTIL  IDIXALOG IDIXCEE  IDIXCM69 IDIXDCAP
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W6900

Applicable component levels

  • RC10 PSY UI18643

       UP14/06/13 P F406

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
01 July 2014