A fix is available
APAR status
Closed as program error.
Error description
Record trace report in OMPE V520 shows incorrect values for some fields comparing to the earlier report versions V520 output : COLLECTION ID : NULLIDSYSSH20002 DST00 SELECT FESTVERS FROM DB2SH.HKP WHERE PLANNR=1 PROGRAM NAME : SYSSH20002 DST00 SELECT FESTVERS FROM DB2SH.HKP WHERE PLANNR=1 FOR FETC CONTOKEN (TS) : X'5359534C564C3031' INDIC CHAR(DEC) : 3 STMT NBR QUERY: 0 PLAN NAME QUERY: DISTSERV STMT ID : 0 STMT TYPE : DYNAMIC SECTION : 65 VERSION LENGTH : 0 VERSION : 'BLANK' correct output in V510 : COLLECTION ID : NULLID PROGRAM NAME : SYSSH200 CONTOKEN (TS) : X'5359534C564C3031' INC FUNC TYPE : TIMESTAMP STRING 3 STMT NBR QUERY : 0 PLAN NAME QUERY: DISTSERV STMT ID : 0 STMT TYPE : DYNAMIC SECTION : 65 VERSION LENGTH : 0 VERSION : 'BLANK' 3: AN UNSUPPORTED CHARACTER STRING REPRESENTATION OF A TIMESTAMP WAS USED.
Local fix
Use earlier version of batch record trace if possible
Problem summary
**************************************************************** * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM * * users of component * * - Batch Reporting * **************************************************************** * PROBLEM DESCRIPTION: Descriptions of fields QW0366PC_VAR * * and QW0366PN_VAR are changed in * * DSNDQW05 macro, so QW0366PC_VAR * * field must be replaced by QW0366PC_D * * and QW0366PN_VAR field by QW0366PN_D. * **************************************************************** * RECOMMENDATION: Apply this PTF * **************************************************************** PROBLEM SUMMARY: Descriptions of fields QW0366PC_VAR and QW0366PN_VAR are changed in DSNDQW05 macro, so QW0366PC_VAR field must be replaced by QW0366PC_D and QW0366PN_VAR field by QW0366PN_D. PROBLEM CONCLUSION: Descriptions of fields QW0366PC_VAR and QW0366PN_VAR are changed in DSNDQW05 macro, so QW0366PC_VAR field must be replaced by QW0366PC_D and QW0366PN_VAR field by QW0366PN_D. KEYWORDS: DSNDQW05 MACRO QW0366PC_VAR QW0366PN_VAR
Problem conclusion
Descriptions of fields QW0366PC_VAR and QW0366PN_VAR are changed in DSNDQW05 macro, so QW0366PC_VAR field must be replaced by QW0366PC_D and QW0366PN_VAR field by QW0366PN_D. KEYWORDS: DSNDQW05 MACRO QW0366PC_VAR QW0366PN_VAR
Temporary fix
Comments
APAR Information
APAR number
PI15377
Reported component name
OM XE DB2PE/PM
Reported component ID
5655OPE00
Reported release
520
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-04-07
Closed date
2014-04-24
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI17338
Modules/Macros
DGONF370
Fix information
Fixed component name
OM XE DB2PE/PM
Fixed component ID
5655OPE00
Applicable component levels
R520 PSY UI17338
UP14/04/26 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]
Document Information
Modified date:
02 May 2014