IBM Support

PI15377: RECORD TRACE REPORT PRODUCES INCORRECT VALUES FOR SOME FIELDS

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Record trace report in OMPE V520 shows incorrect values for some
    fields comparing to the earlier report versions
    
    V520 output :
    
    
       COLLECTION ID    :  NULLIDSYSSH20002 DST00     SELECT
    FESTVERS FROM
    DB2SH.HKP WHERE PLANNR=1
       PROGRAM NAME     :  SYSSH20002 DST00     SELECT FESTVERS FROM
    DB2SH.HKP WHERE PLANNR=1 FOR FETC
       CONTOKEN (TS)    : X'5359534C564C3031'
       INDIC CHAR(DEC)  :                     3 STMT NBR QUERY:
    0
    PLAN NAME QUERY: DISTSERV
       STMT ID          :                    0  STMT TYPE     :
    DYNAMIC
    SECTION        :         65
       VERSION LENGTH :                       0 VERSION       :
    'BLANK'
    
    correct output in V510 :
    
       COLLECTION ID  : NULLID
       PROGRAM NAME   : SYSSH200
       CONTOKEN (TS)  : X'5359534C564C3031'
       INC FUNC TYPE  : TIMESTAMP STRING  3  STMT NBR QUERY :
    0
    PLAN NAME QUERY: DISTSERV
       STMT ID      :                     0  STMT TYPE      :
    DYNAMIC
    SECTION        :         65
       VERSION LENGTH :                   0  VERSION        :
    'BLANK'
    
    3: AN UNSUPPORTED CHARACTER STRING REPRESENTATION OF A TIMESTAMP
    WAS USED.
    

Local fix

  • Use earlier version of batch record trace if possible
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: OMEGAMON XE for DB2 PE/DB2PM                 *
    *                 users of component                           *
    *                 - Batch Reporting                            *
    ****************************************************************
    * PROBLEM DESCRIPTION: Descriptions of fields QW0366PC_VAR     *
    *                      and QW0366PN_VAR are changed in         *
    *                      DSNDQW05 macro, so QW0366PC_VAR         *
    *                      field must be replaced by QW0366PC_D    *
    *                      and QW0366PN_VAR field by QW0366PN_D.   *
    ****************************************************************
    * RECOMMENDATION: Apply this PTF                               *
    ****************************************************************
    PROBLEM SUMMARY:
    Descriptions of fields QW0366PC_VAR and QW0366PN_VAR
    are changed in DSNDQW05 macro, so QW0366PC_VAR field
    must be replaced by QW0366PC_D and QW0366PN_VAR field
    by QW0366PN_D.
    
    PROBLEM CONCLUSION:
    Descriptions of fields QW0366PC_VAR and QW0366PN_VAR
    are changed in DSNDQW05 macro, so QW0366PC_VAR field
    must be replaced by QW0366PC_D and QW0366PN_VAR field
    by QW0366PN_D.
    
    KEYWORDS:
    DSNDQW05 MACRO QW0366PC_VAR QW0366PN_VAR
    

Problem conclusion

  • Descriptions of fields QW0366PC_VAR and QW0366PN_VAR
    are changed in DSNDQW05 macro, so QW0366PC_VAR field
    must be replaced by QW0366PC_D and QW0366PN_VAR field
    by QW0366PN_D.
    
    KEYWORDS:
    DSNDQW05 MACRO QW0366PC_VAR QW0366PN_VAR
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI15377

  • Reported component name

    OM XE DB2PE/PM

  • Reported component ID

    5655OPE00

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-07

  • Closed date

    2014-04-24

  • Last modified date

    2014-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI17338

Modules/Macros

  • DGONF370
    

Fix information

  • Fixed component name

    OM XE DB2PE/PM

  • Fixed component ID

    5655OPE00

Applicable component levels

  • R520 PSY UI17338

       UP14/04/26 P F404

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSAV2B","label":"IBM Db2 Buffer Pool Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}},{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCT4H5","label":"IBM Tivoli OMEGAMON XE for Db2 PE \/ PM \/ BPA"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"5.2.0","Edition":"","Line of Business":{"code":"LOB10","label":"Data and AI"}}]

Document Information

Modified date: