IBM Support

PI11195: TODAY FUNCTION IN RULE DOES NOT UPDATE CELL AFTER DATE CHANGE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as fixed if next.

Error description

  • The TODAY() function in a TM1 rule does not update cell after
    date changes on the system. ??In TM1 9.5.2 the following rule
    would be triggered automatically when the system date changed
    (either by the day changing or by manually setting the system
    date).??['A','1'] = n:DAYNO(TODAY(1)) + 21916;??In 10.2 we must
    restart TM1, run CubeProcessFeeders or recompile the rules for
    this rule to be triggered and update the cell with the current
    date.??Adding a feeder does not help (see example
    below)??SKIPCHECK;?['A','1'] = n:DAYNO(TODAY(1)) +
    21916;?????FEEDERS;?['A'] => ['A','1'];??We believe this is a
    defect since this worked in 9.5.2 but not 10.2. We are currently
    working around the problem by using a Ti process to set the date
    in this cell.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * See error description                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Please upgrade to TM1 10.2.2                                 *
    ****************************************************************
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI11195

  • Reported component name

    TM1 SERVER

  • Reported component ID

    5724W49SE

  • Reported release

    A20

  • Status

    CLOSED FIN

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-02-06

  • Closed date

    2014-05-13

  • Last modified date

    2014-05-13

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

  • RA22 PSN

       UP

[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SS9RXT","label":"Cognos TM1"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"10.2","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
21 September 2021