IBM Support

PI11057: MISCELLANEOUS BUG FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 11 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. Incorrect Compiler Listing display  *
    *                          pseudo assembler instructions       *
    *                          default setting.                    *
    *                          APAR PI16323                        *
    *                      02. Abend S0C4 in IDIXDCAP with         *
    *                          messages IDI0012S and IDI0013S.     *
    *                          APAR PI16324                        *
    *                      03. Fault Analyzer loop when trying to  *
    *                          display Java event.                 *
    *                          APAR PI16325                        *
    *                      04. CICS formatted trace entries are    *
    *                          missing location information        *
    *                          following the colon, as in          *
    *                          "Called-from-address <address> :    *
    *                          <location>".                        *
    *                          APAR PI16326                        *
    *                      05. Too many allocations of the Fault   *
    *                          Analyzer history file.              *
    *                          APAR PI16213                        *
    *                      06. Console flooded with IDI0088E       *
    *                          messages.                           *
    *                          APAR PI16215                        *
    *                      07. Fault Analyzer IMS BMP user ID      *
    *                          wrong.                              *
    *                          APAR PI16327                        *
    *                      08. IDILANGX ends with CEE0802C at      *
    *                          entry point LSMMFREE.               *
    *                          APAR PI16218                        *
    *                      09. IMS MPP terminating but does not    *
    *                          end.                                *
    *                          APAR PI16328                        *
    *                      10. Message IDI0131W Waiting for        *
    *                          history-file($$INDEX) SPFEDIT ENQ   *
    *                          when ENQ is held by a TSO user.     *
    *                          APAR PI16329                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. The product default, when the user has not yet selected
        either "Add Pseudo Assembler Instructions" or "Remove Pseudo
        Assembler Instructions" from the action-bar View pull-down
        menu, is to show the pseudo assembler instructions.  This is
        incorrect according to the documentation.
    02. A zero value while looping through a set of data was not
        being correctly allowed for.
    03. If a Java source file can not be successfully opened, then
        the code might loop.
    04. 64-bit addresses were not handled correctly.
    05. A frequently used system service is causing dynamic
        allocation.
    06. Storage abend during ESTAE recovery while invoking the
        Binder program.
    07. The user ID reported by Fault Analyzer for a BMP might be
        the program name instead of the user ID.
    08. Max locates records causes write buffer overrun.
    09. The MPP termination was held up by Fault Analyzer processing
        that had stalled.
    10. Abend in a TSO screen running Fault Analyzer might leave the
        $$INDEX ENQ outstanding until the TSO session is logged off.
    

Problem conclusion

  • 01. The product default has been changed to not include the
        pseudo assembler instructions in the Compiler Listing
        display.
    02. A zero value is now correctly handled.
    03. The code has been corrected to prevent the loop.
    04. 64-bit addresses are now being handled correctly.
    05. The system service is now called using pre-allocation.
    06. The ESTAE is now cancelled before activity requiring virtual
        storage occurs.
    07. The code has been corrected to ensure the input IOPCB user
        ID is only used for IMS message processing regions.
    08. Max locates records reduced to fit write buffer.
    09. Monitor task added to ensure the IDIDA TCB attaches and runs
        successfully.
    10. Code added to help DEQ processing in the case of Fault
        Analyzer abending in TSO/ISPF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI11057

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W4600

  • Reported release

    B10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-02-04

  • Closed date

    2014-04-24

  • Last modified date

    2014-05-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI17320

Modules/Macros

  • HADQB10J IDICAASM IDICABND IDICALE  IDICALOC IDICASUB IDICCFND
    IDICISA  IDICOPYR IDICSV11 IDICSV14 IDIDA
    
    ***This field was truncated.  To obtain the full apar record, please contact your local support center.***
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W4600

Applicable component levels

  • RB10 PSY UI17320

       UP14/05/01 P F404

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 May 2014