A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 13 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. Incorrect Compiler Listing display * * pseudo assembler instructions * * default setting. * * APAR PI11288 * * 02. Abend S0C4 in IDIXDCAP with * * messages IDI0012S and IDI0013S. * * APAR PI16310 * * 03. Fault Analyzer loop when trying to * * display Java event. * * APAR PI16311 * * 04. CICS formatted trace entries are * * missing location information * * following the colon, as in * * "Called-from-address <address> : * * <location>". * * APAR PI16312 * * 05. Too many allocations of the Fault * * Analyzer history file. * * APAR PI16313 * * 06. Console flooded with IDI0088E * * messages. * * APAR PI16314 * * 07. CICS SDUMP PI Domain panels * * display incorrect information. * * APAR PI16315 * * 08. Fault Analyzer IMS BMP user ID * * wrong. * * APAR PI16316 * * 09. Message IDI0131W Waiting for * * history-file($$INDEX) SPFEDIT ENQ * * when ENQ is held by a TSO user. * * APAR PI16317 * * 10. IMS MPP terminating but does not * * end. * * APAR PI16318 * * 11. CICS abend ASRA in XEIIN GLUE with * * CICS/TS 3.2. * * APAR PI16464 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. The product default, when the user has not yet selected either "Add Pseudo Assembler Instructions" or "Remove Pseudo Assembler Instructions" from the action-bar View pull-down menu, is to show the pseudo assembler instructions. This is incorrect according to the documentation. 02. A zero value while looping through a set of data was not being correctly allowed for. 03. If a Java source file can not be successfully opened, then the code might loop. 04. 64-bit addresses were not handled correctly. 05. A frequently used system service is causing dynamic allocation. 06. Storage abend during ESTAE recovery while invoking the Binder program. 07. CICS has changed the offsets of some fields within the PI domain control blocks. 08. The user ID reported by Fault Analyzer for a BMP might be the program name instead of the user ID. 09. Abend in a TSO screen running Fault Analyzer might leave the $$INDEX ENQ outstanding until the TSO session is logged off. 10. The MPP termination was held up by Fault Analyzer processing that had stalled. 11. An incorrect CICS XPI command was being used with CICS/TS 3.2.
Problem conclusion
01. The product default has been changed to not include the pseudo assembler instructions in the Compiler Listing display. 02. A zero value is now correctly handled. 03. The code has been corrected to prevent the loop. 04. 64-bit addresses are now being handled correctly. 05. The system service is now called using pre-allocation. 06. The ESTAE is now cancelled before activity requiring virtual storage occurs. 07. Fault Analyzer has been changed to use correct offsets for the PI domain. 08. The code has been corrected to ensure the input IOPCB user ID is only used for IMS message processing regions. 09. Code added to help DEQ processing in the case of Fault Analyzer abending in TSO/ISPF. 10. Monitor task added to ensure the IDIDA TCB attaches and runs successfully. 11. The XPI command has been corrected.
Temporary fix
Comments
APAR Information
APAR number
PI11055
Reported component name
FAULT ANALYZER
Reported component ID
5655Q1100
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2014-02-04
Closed date
2014-04-22
Last modified date
2014-05-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI17255
Modules/Macros
HADQD10J IDICAASM IDICABND IDICALE IDICALOC IDICASUB IDICCFND IDICISA IDICOPYR IDICSV11 IDICSV14 IDIDA IDIDASUB IDIDATST IDIGMAIN IDIHPMSG IDIMCICS IDINDEX IDIPDDIR IDIPDSCU IDISAMAN IDISAQUE IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJAX IDISJLD IDISJLOG IDISLEEP IDISLKUP IDISLOG IDISMAIN IDISREG IDISRFRA IDISRFRD IDISTIME IDISUPDI IDISVIEW IDIUGPDF IDIUTIL IDIXALOG IDIXASUB IDIXCCEE IDIXCC52 IDIXCEE IDIXCE53 IDIXCE67 IDIXCE68 IDIXCE69 IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCX52 IDIXCX53 IDIXDCAP IDIXDSAC IDIXDUMP IDIXGSPC IDIXGSPS IDIXOPT IDIXSNAP IDIXTSEL
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655Q1100
Applicable component levels
RD10 PSY UI17255
UP14/04/29 P F404
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
02 May 2014