Error description

  • Miscellaneous bug fixes.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Fault Analyzer Version 12 users.         *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01. FAISPFopts(InitHist(View(xxx)))     *
    *                          option not taking effect.           *
    *                          APAR PI05961                        *
    *                      02. Abend S23E after successful Fault   *
    *                          Analyzer analysis of a CICS         *
    *                          transaction abend.                  *
    *                          APAR PI07757                        *
    *                      03. MATCH CSR not working if help text  *
    *                          is enabled, the display has been    *
    *                          scrolled to hide the help text, and *
    *                          the cursor is placed in a field     *
    *                          near the bottom of the display.     *
    *                          APAR PI07758                        *
    *                      04. Fault Analyzer IDIS subsystem       *
    *                          IDI0095W ENQ ECB status error and   *
    *                          IDI0131W ENQ delay lockout on       *
    *                          history file.                       *
    *                          APAR PI06731                        *
    *                      05. Extraneous subscript when           *
    *                          formatting multi-dimension COBOL    *
    *                          tables.                             *
    *                          APAR PI07759                        *
    *                      06. Storage overlay in fileLANGX()      *
    *                          while processing scope records.     *
    *                          APAR PI06856                        *
    *                      07. Fault Analyzer gets a S0C4 abend    *
    *                          at entry point pp_tctse_main when   *
    *                          analyzing a dump.                   *
    *                          APAR PI07743                        *
    *                      08. Abend S0C4 from entry point         *
    *                          ProcHistDA statement 6965 offset    *
    *                          X'81BA' when pressing Enter after   *
    *                          selecting an empty history file for *
    *                          display.                            *
    *                          APAR PI07106                        *
    *                      09. Incorrect Fault Entry List display  *
    *                          scroll down action under CICS, when *
    *                          help text is enabled and the        *
    *                          top-most fault entry is displayed.  *
    *                          APAR PI07758                        *
    *                      10. Symbol substitution not working     *
    *                          in the alternative parmlib data set *
    *                          name specified via the IDIOPTLM     *
    *                          configuration-options module field  *
    *                          CNFDSN.                             *
    *                          APAR PI07405                        *
    *                      11. The user ID of an IMS abend is not  *
    *                          displayed in the history file, like *
    *                          it is for CICS.                     *
    *                          APAR PI07760                        *
    *                      12. Message "ICH409I 282-020 ABEND      *
    *                          DURING RACHECK PROCESSING" during   *
    *                          analysis of Java dump.              *
    *                          APAR PI07740                        *
    *                      13. Fault Analyzer empty report, no     *
    *                          events from RFR dump after IDI0055S *
    *                          out of storage message.             *
    *                          APAR PI07742                        *
    *                      14. Fault Analyzer might generate more  *
    *                          than one fault entry for the same   *
    *                          event.  The additional fault        *
    *                          entries have no minidump or report  *
    *                          content.                            *
    *                          APAR PI07784                        *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    01. A check for an initialized default view name failed to
        recognize blanks as an uninitialized name.
    02. For LE transactions running on a L9 TCB, control was being
        returned to the Fault Analyzer invocation exit on the L9
        TCB. A DETACH call could potentially be issued, which is not
        valid from the L9 TCB.
    03. The check for the cursor position within the ISPF dynamic
        area failed to correctly cater for the hidden help text.
    04. When XCF message delays occur, the IDIS subsystem recovery
        might get an ENQ status error that causes recurring IDI0131W
        messages until the IDIS subsystem is restarted.
    05. Dimension not decremented correctly.
    06. Scope slot index is out of bounds.
    07. A storage overlay in the customer environment caused control
        blocks to contain invalid values. A text string was missing
        the terminating character, causing Fault Analyzer to get a
        S0C4.
    08. The determination of display characteristics to be used for
        the re-display did not correctly handle the situation where
        the history file contains zero fault entries.
    09. The ZSCROLLA value returned by VGET in this environment
        was not blank-padded as expected.
    10. The symbol substitution service output buffer length was
        set too short.
    11. The user ID displayed is the one from the job's ACEE.
    12. A valid history file data set name had not been set from the
        Fault Entry List display prior to the dump analysis,
        resulting in a blank history file data set name being
        checked for access authorization.
    13. The RFR SDUMP after an out of storage IDI0055S message might
        not get a TCB selected for analysis.
    14. More than one fault entry for the same job and timestamp if
        delays in XCF coupling facility messages cause retransmit of
        a fault ID assignment.
    

Problem conclusion

  • 01. The check for an initialized default view name has been
        corrected.
    02. The DETACH is now only attempted when running on the QR TCB.
    03. The problem has been corrected.
    04. ENQ processing changed to accommodate the timing issues.
    05. Dimension decremented corrected.
    06. Scope slot index corrected.
    07. The code was modified to limit the length of the string
        processed.
    08. The problem has been corrected.
    09. The ZSCROLLA value is now processed correctly, regardless of
        blank-padding after VGET.
    10. The buffer length has been set to the correct value.
    11. If a user ID is found in an IMS IOPCB, then it will be shown
        instead of the job's ACEE user ID.
    12. A check has been added for the existence of a non-blank
        history file data set name prior to the RACHECK call.
    13. The code has bee updated to determine the TCB issuing the
        RFR call.
    14. The code has been updated to cater for the potential
        re-transmission of an assignment request via XCF.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI06354

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655W6900

  • Reported release

    C10

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2013-11-17

  • Closed date

    2013-12-11

  • Last modified date

    2014-01-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UI13466 128AC7Ÿ

Modules/Macros

  • HADQC10J IDICAASM IDICABND IDICADYN IDICALE  IDICALOC IDICASUB
    IDICBDB2 IDICCFND IDICISA  IDICISA2 IDICNF00 IDICNOTR IDICOPYR
    IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICSMF  IDICSPC  IDICSVCR
    IDICSV14 IDICUXCS IDICUXWR IDIDA    IDIDATSA IDIDATST IDIEDPIE
    IDIEEDE  IDIGMAIN IDIGNTCE IDIGUIP  IDIGWEB  IDIGWEBB IDIHE003
    IDIHIBMM IDIHPMSG IDIHUSRM IDIMCICS IDIM03   IDIM04   IDIM06
    IDIM07   IDINDEX  IDIPASUB IDIPBRWS IDIPCTRF IDIPDDIR IDIPDSCU
    IDIPHC00 IDIPHC01 IDIPHC02 IDIPHC07 IDIPHI04 IDIPHI06 IDIPHI07
    IDIPHI09 IDIPHL01 IDIPHO02 IDIPHS00 IDIPH000 IDIPH001 IDIPH002
    IDIPH003 IDIPH004 IDIPH005 IDIPH006 IDIPH007 IDIPH111 IDIPH112
    IDIPH113 IDIPH114 IDIPH115 IDIPH116 IDIPH117 IDIPH118 IDIPH119
    IDIPH120 IDIPH121 IDIPH122 IDIPH123 IDIPH124 IDIPH125 IDIPH126
    IDIPH127 IDIPH128 IDIPH129 IDIPH130 IDIPH131 IDIPH132 IDIPH133
    IDIPH134 IDIPH137 IDIPH138 IDIPH139 IDIPH140 IDIPH141 IDIPH143
    IDIPH148 IDIPH154 IDIPH158 IDIPH210 IDIPH211 IDIPH215 IDIPH216
    IDIPH218 IDIPH236 IDIPH237 IDIPH238 IDIPIDAD IDIPILPT IDIPLDSN
    IDIPLT   IDIS$NDX IDISAMAN IDISAQUE IDISAREQ IDISASUB IDISBRW2
    IDISCICS IDISCJST IDISDB2P IDISDB2S IDISFESK IDISFPEX IDISIFND
    IDISJAX  IDISJL   IDISJLD  IDISJLOG IDISLKUP IDISLOG  IDISMAIN
    IDISREG  IDISRFRA IDISRFRD IDISRP02 IDISSREQ IDISS254 IDISTIME
    IDISUPDI IDISVIEW IDISWRAP IDISXCFA IDISXPLA IDISXPLB IDISXPLC
    IDISXPLP IDITABD  IDIUGPDF IDIUTIL  IDIVPCOB IDIVPPLE IDIVPPLI
    IDIWH001 IDIWP002 IDIXALGL IDIXALOG IDIXAPI  IDIXASUB IDIXATT
    IDIXCCEE IDIXCC52 IDIXCEE  IDIXCE53 IDIXCE67 IDIXCE68 IDIXCE69
    IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCXUM IDIXCX52 IDIXCX53
    IDIXDCAP IDIXDSAC IDIXDUMP IDIXFA   IDIXGSPC IDIXGSPS IDIXJAVA
    IDIXMAP  IDIXOPT  IDIXSNAP IDIXTSEL
    

Fix information

  • Fixed component name

    FAULT ANALYZER

  • Fixed component ID

    5655W6900

Applicable component levels

  • RC10 PSY UI13466

       UP13/12/17 P F312

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"","label":""}},{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"C10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
02 January 2014