A fix is available
APAR status
Closed as program error.
Error description
Miscellaneous bug fixes.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Fault Analyzer Version 13 users. * **************************************************************** * PROBLEM DESCRIPTION: 01. FAISPFopts(InitHist(View(xxx))) * * option not taking effect. * * APAR PI07744 * * 02. Abend S23E after successful Fault * * Analyzer analysis of a CICS * * transaction abend. * * APAR PI07745 * * 03. MATCH CSR not working if help text * * is enabled, the display has been * * scrolled to hide the help text, and * * the cursor is placed in a field * * near the bottom of the display. * * APAR PI07746 * * 04. Extraneous subscript when * * formatting multi-dimension COBOL * * tables. * * APAR PI07747 * * 05. Fault Analyzer IDIS subsystem * * IDI0095W ENQ ECB status error and * * IDI0131WENQ delay lockout on * * history file. * * APAR PI07748 * * 06. Storage overlay in fileLANGX() * * while processing scope records. * * APAR PI07749 * * 07. Fault Analyzer gets a S0C4 abend * * at entry point pp_tctse_main when * * analyzing a dump. * * APAR PI07750 * * 08. Abend S0C4 from entry point * * ProcHistDA statement 6965 offset * * X'81BA' when pressing Enter after * * selecting an empty history file for * * display. * * APAR PI07751 * * 09. Incorrect Fault Entry List display * * scroll down action under CICS, when * * help text is enabled and the * * top-most fault entry is displayed. * * APAR PI07746 * * 10. Symbol substitution not working * * in the alternative parmlib data set * * name specified via the IDIOPTLM * * configuration-options module field * * CNFDSN. * * APAR PI07753 * * 11. The user ID of an IMS abend is not * * displayed in the history file, like * * it is for CICS. * * APAR PI07754 * * 12. Message "ICH409I 282-020 ABEND * * DURING RACHECK PROCESSING" during * * analysis of Java dump. * * APAR PI07755 * * 13. Fault Analyzer empty report, no * * events from RFR dump after IDI0055S * * out of storage message. * * APAR PI07756 * * 14. Fault Analyzer might generate more * * than one fault entry for the same * * event. The additional fault * * entries have no minidump or report * * content. * * APAR PI07857 * **************************************************************** * RECOMMENDATION: Apply the provided PTF. * **************************************************************** 01. A check for an initialized default view name failed to recognize blanks as an uninitialized name. 02. For LE transactions running on a L9 TCB, control was being returned to the Fault Analyzer invocation exit on the L9 TCB. A DETACH call could potentially be issued, which is not valid from the L9 TCB. 03. The check for the cursor position within the ISPF dynamic area failed to correctly cater for the hidden help text. 04. Dimension not decremented correctly. 05. When XCF message delays occur, the IDIS subsystem recovery might get an ENQ status error that causes recurring IDI0131W messages until the IDIS subsystem is restarted. 06. Scope slot index is out of bounds. 07. A storage overlay in the customer environment caused control blocks to contain invalid values. A text string was missing the terminating character, causing Fault Analyzer to get a S0C4. 08. The determination of display characteristics to be used for the re-display did not correctly handle the situation where the history file contains zero fault entries. 09. The ZSCROLLA value returned by VGET in this environment was not blank-padded as expected. 10. The symbol substitution service output buffer length was set too short. 11. The user ID displayed is the one from the job's ACEE. 12. A valid history file data set name had not been set from the Fault Entry List display prior to the dump analysis, resulting in a blank history file data set name being checked for access authorization. 13. The RFR SDUMP after an out of storage IDI0055S message might not get a TCB selected for analysis. 14. More than one fault entry for the same job and timestamp if delays in XCF coupling facility messages cause retransmit of a fault ID assignment.
Problem conclusion
01. The check for an initialized default view name has been corrected. 02. The DETACH is now only attempted when running on the QR TCB. 03. The problem has been corrected. 04. Dimension decremented corrected. 05. ENQ processing changed to accommodate the timing issues. 06. Scope slot index corrected. 07. The code was modified to limit the length of the string processed. 08. The problem has been corrected. 09. The ZSCROLLA value is now processed correctly, regardless of blank-padding after VGET. 10. The buffer length has been set to the correct value. 11. If a user ID is found in an IMS IOPCB, then it will be shown instead of the job's ACEE user ID. 12. A check has been added for the existence of a non-blank history file data set name prior to the RACHECK call. 13. The code has bee updated to determine the TCB issuing the RFR call. 14. The code has been updated to cater for the potential re-transmission of an assignment request via XCF.
Temporary fix
Comments
APAR Information
APAR number
PI06353
Reported component name
FAULT ANALYZER
Reported component ID
5655Q1100
Reported release
D10
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-11-17
Closed date
2013-12-11
Last modified date
2014-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UI13465
Modules/Macros
HADQD10J IDICABND IDICADYN IDICASUB IDICBDB2 IDICCFND IDICNOTR IDICOPYR IDICRXDX IDICRXEI IDICRXET IDICRXHC IDICSMF IDICSPC IDICUXCS IDICUXWR IDIDA IDIDATST IDIGMAIN IDIGWEBB IDIHPMSG IDIMCICS IDINDEX IDIPDDIR IDIPDSCU IDIPHC00 IDIPHC01 IDIPHC02 IDIPHC07 IDIPHI04 IDIPHI06 IDIPHI07 IDIPHI09 IDIPHS00 IDIPH000 IDIPH001 IDIPH002 IDIPH003 IDIPH004 IDIPH006 IDIPH007 IDIPH111 IDIPH112 IDIPH113 IDIPH114 IDIPH115 IDIPH116 IDIPH117 IDIPH118 IDIPH119 IDIPH120 IDIPH121 IDIPH122 IDIPH123 IDIPH124 IDIPH125 IDIPH126 IDIPH127 IDIPH128 IDIPH129 IDIPH130 IDIPH131 IDIPH132 IDIPH133 IDIPH137 IDIPH138 IDIPH139 IDIPH140 IDIPH141 IDIPH143 IDIPH148 IDIPH158 IDIPH210 IDIPH211 IDIPH215 IDIPH216 IDIPH218 IDIPH236 IDIPH237 IDIPH238 IDIPLT IDISAMAN IDISAQUE IDISAREQ IDISASUB IDISBBGA IDISBBGS IDISCJST IDISDB2P IDISDB2S IDISFPEX IDISIFND IDISJL IDISJLD IDISJLOG IDISLKUP IDISLOG IDISMAIN IDISREG IDISRFRA IDISRFRD IDISSREQ IDISS254 IDISTIME IDISUPDI IDISVIEW IDISXCFA IDIUGPDF IDIUTIL IDIXALGL IDIXALOG IDIXASUB IDIXCCEE IDIXCE69 IDIXCM53 IDIXCM67 IDIXCM68 IDIXCM69 IDIXCX53 IDIXDSAC IDIXDUMP IDIXGSPC IDIXGSPS IDIXOPT IDIXTSEL
Fix information
Fixed component name
FAULT ANALYZER
Fixed component ID
5655Q1100
Applicable component levels
RD10 PSY UI13465
UP13/12/17 P F312
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"D10","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]