Error description
Fault Analyzer minidump pages was exceeded (FA option MaxMinidumpPages) in a CICS environment, causing Fault Analyzer to write a real-time report. The value specified for option StoragePrintLimit was not honored, and a very large report was being written, causing the CICS region to abend with S878 and terminate at end of memory. The following Fault Analyzer message is also received: IDI0011S Abend 878000 occurred during Fault Analyzer analysis
Local fix
Possible circumventions: 1) increase value specified for MaxMinidumpPages option (the maximum is 524288) 2) enable Fault Analyzer XDUMPs (preferred circumvention)
Problem summary
Problem conclusion
Temporary fix
Comments
Closed as DUP of FA 14.1.18 Miscellaneous Bug Fixes APAR PH49436