IBM Support

PH50202: FAULT ANALYZER MESSAGE IDI0011S IS RECEIVED IN A CICS REGION, CAUSING FAULT ANALYZER AND CICS ABEND S878.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • Fault Analyzer minidump pages was exceeded (FA option
    MaxMinidumpPages) in a CICS environment, causing Fault Analyzer
    to write a real-time report.  The value specified for option
    StoragePrintLimit was not honored, and a very large report was
    being written, causing the CICS region to abend with S878 and
    terminate at end of memory.  The following Fault Analyzer
    message is also received:
    IDI0011S Abend 878000 occurred during Fault Analyzer analysis
    

Local fix

  • Possible circumventions:
    1) increase value specified for MaxMinidumpPages option (the
    maximum is 524288)
    2) enable Fault Analyzer XDUMPs   (preferred circumvention)
    

Problem summary

Problem conclusion

Temporary fix

Comments

  • Closed as DUP of FA 14.1.18 Miscellaneous Bug Fixes APAR PH49436
    

APAR Information

  • APAR number

    PH50202

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655Q4100

  • Reported release

    E10

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-10-14

  • Closed date

    2022-11-18

  • Last modified date

    2022-11-18

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

Applicable component levels

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXJAJ","label":"Fault Analyzer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E10","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
18 November 2022