IBM Support

PH47519: RECEIVE S0C4 AFTER ENTERING A FIND COMMAND WHEN VIEWING THE CICS TRACE DURING FAULT ANALYZER INTERACTIVE REANALYSIS.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as duplicate of another APAR.

Error description

  • During Fault Analyzer interactive reanalysis of a SVC dump, and
    viewing the CICS trace, when a Find command is entered the
    following messages are received:
     CEE3204S The system detected a protection exception (System
    Completion Code=0C4).
     From entry point ProcTraceDA at ...
     IDI0047S IBM Fault Analyzer internal abend. S0C4
    

Local fix

Problem summary

Problem conclusion

Temporary fix

Comments

  • Closed as DUP of 14.1.17+ Miscellaneous Bug Fixes APAR PH47248.
    

APAR Information

  • APAR number

    PH47519

  • Reported component name

    FAULT ANALYZER

  • Reported component ID

    5655Q4100

  • Reported release

    E10

  • Status

    CLOSED DUB

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2022-06-25

  • Closed date

    2022-09-12

  • Last modified date

    2022-09-12