IBM Support

PH35089: z/OS Connect EE API provider truncates decimal defined fields.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as unreproducible in next release.

Error description

  • When z/OS Connect EE is processing decimal fields with more than
    17 digits, the decimal fields are truncated to 17 digits and
    reformatted as floating point.
    
    Example: For a COBOL definition of PIC 9(13)V9(5), the field is
    defined as Decimal(18). When 3333333333333.55555 is sent
    to z/OS Connect EE, the data received in the SOR is
    333333333333355570.
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of z/OS Connect EE V3.0 API        *
    *                 provider using large decimal numbers.        *
    ****************************************************************
    * PROBLEM DESCRIPTION: z/OS Connect EE API provider truncates  *
    *                      decimal defined fields.                 *
    ****************************************************************
    The translation of numbers between the JSON number format and
    API provider payload resulted in incorrect values being used.
    This was because decimal values with a lot of numbers were not
    translated correctly.
    
    If the field was defined as a string, rather than a decimal
    value the problem did not occur.
    
    A similar issue for z/OS Connect EE API requesters was resolved
    by APAR PH30400.
    

Problem conclusion

Temporary fix

Comments

  • The z/OS Connect EE API provider code has been updated to
    correctly translate decimal numbers with a large number of
    digits and pass these to back-end applications.
    
    The fix for this APAR is expected to be delivered by the PTF for
    z/OS Connect EE V3.0.53.0 (PH42641).
    

APAR Information

  • APAR number

    PH35089

  • Reported component name

    Z/OS CONNECT EE

  • Reported component ID

    5655CE300

  • Reported release

    000

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2021-03-05

  • Closed date

    2022-01-04

  • Last modified date

    2022-01-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    Z/OS CONNECT EE

  • Fixed component ID

    5655CE300

Applicable component levels

[{"Line of Business":{"code":"LOB35","label":"Mainframe SW"},"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSNPJM","label":"IBM z\/OS Connect"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"3.0"}]

Document Information