IBM Support

PH29587: ABO OPTIMIZED MODULE ABENDS WITH 'S806 CEE3501S THE MODULE ........ WAS NOT FOUND'

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Abend S806 CEE3501S The module ........ was not found.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of the IBM Automatic Binary Optimizer  *
    *                 (ABO) 2.1 Trial March 2020 PTF               *
    ****************************************************************
    * PROBLEM DESCRIPTION: In some rare situations, COBOL-compiled *
    *                      programs containing multiple fall-      *
    *                      through PERFORM statements may be       *
    *                      optimized incorrectly by ABO. For       *
    *                      example,                                *
    *                      PERFORM A THRU A-END                    *
    *                      PERFORM B THRU B-END                    *
    *                      A.                                      *
    *                         PROGRAM STATEMENT                    *
    *                      A-END.                                  *
    *                      B.                                      *
    *                         PROGRAM STATEMENT                    *
    *                      B-END                                   *
    *                      Symptoms may be "ABEND S806 CEE3501S    *
    *                      The module ........ was not found" but  *
    *                      other unexpected behavior, abends and   *
    *                      wrong results are also possible.        *
    *                                                              *
    *                      This APAR addresses such issues by      *
    *                      allowing ABO to generate Program        *
    *                      complexity messages in such situations  *
    *                      and skip optimization of the CSECT.     *
    ****************************************************************
    * RECOMMENDATION: Apply provided service                       *
    ****************************************************************
    The ABO 2.1 Trial was modified to include the above item
    from September 2020 ABO 2.1 PTF
    

Problem conclusion

  • The ABO 2.1 Trial now includes the above item from the
    September 2020 ABO 2.1 PTF
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH29587

  • Reported component name

    AUTO BIN OPT TR

  • Reported component ID

    5697TR200

  • Reported release

    210

  • Status

    CLOSED PER

  • PE

    YesPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2020-09-16

  • Closed date

    2020-09-17

  • Last modified date

    2020-10-02

  • APAR is sysrouted FROM one or more of the following:

    PH29403

  • APAR is sysrouted TO one or more of the following:

    UI71615 UI71616

Modules/Macros

  • BOZBXITA BOZEXE1  BOZJIVP  BOZMSGE  BOZMSGK  BOZMSGT  BOZOBJ1
    BOZOPT   BOZRIDT  BOZSRC1
    

Fix information

  • Fixed component name

    AUTO BIN OPT TR

  • Fixed component ID

    5697TR200

Applicable component levels

  • R210 PSY UI71615

       UP20/09/19 P F009 {

  • R21J PSY UI71616

       UP20/09/19 P F009 {

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF054","label":"z\/OS"}],"Version":"210"}]

Document Information

Modified date:
05 October 2020