PH11555: PROGRAM PRODUCES AN INCORRECT RESULT

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • *************************************************
    **            Defect Fix Template              **
    *************************************************
    
    USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling
    programs at ARCH(10|11) that contain a
    sequence of consecutive computations
    involving PACKED-DECIMAL or USAGE DISPLAY
    data items with differing numbers of digits
    after the decimal place.
    
    PROBLEM DESCRIPTION: Program produces an incorrect result
    
    RECOMMENDATION TO CUSTOMER: Apply the provided PTF
    
    PROBLEM SUMMARY: At ARCH(10) and ARCH(11), the compiler will
    often generate
    Decimal Floating Point (DFP) instructions to perform
    PACKED-DECIMAL or USAGE DISPLAY arithmetic. When combining
    truncation operations with alignment-shifting operations (to
    align the decimal points in data items with different numbers
    of
    digits to the right of the decimal point), the compiler was
    incorrectly generating an incorrect alignment shift, causing an
    intermediate value to incorrectly become zero.
    
    CONCLUSION: The compiler was fixed to generate the correct
    alignment shifts
    when using DFP instructions.
    

Local fix

  • Compile at OPT(0), ARCH(9) or lower, or ARCH(12)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.1 compiling     *
    *                 programs at ARCH(10|11) that contain a       *
    *                 sequence of consecutive computations         *
    *                 involving PACKED-DECIMAL or USAGE            *
    *                 DISPLAY data items with differing numbers of *
    *                 digits after the decimal place.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: Program produces an incorrect result.   *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF.                      *
    ****************************************************************
    At ARCH(10) and ARCH(11), the compiler will often generate
    Decimal Floating Point (DFP) instructions to perform
    PACKED-DECIMAL or USAGE DISPLAY arithmetic. When
    combining truncation operations with alignment-shifting
    operations (to align the decimal points in data items with
    different numbers of digits to the right of the decimal point),
    the compiler was incorrectly generating an incorrect alignment
    shift, causing an intermediate value to incorrectly become zero.
    

Problem conclusion

  • The compiler was fixed to generate the correct alignment shifts
    when using DFP instructions.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH11555

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    610

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-04-29

  • Closed date

    2019-06-12

  • Last modified date

    2019-07-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    PH11948

Modules/Macros

  • IGY8RWTU IGYCCBE  IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG IGYCDMAP
    IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5 IGYCEN$8
    IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0 IGYCJA$1
    IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D IGYCJA$R
    IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1 IGYCLVL2
    IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL IGYCRDPR
    IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0 IGYCUE$1
    IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D IGYCUE$R
    IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK  IGYMSGT  IGYQCBE
    IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R610 PSY UI63606

       UP19/06/18 P F906

  • R611 PSY UI63607

       UP19/06/19 P F906

  • R612 PSY UI63608

       UP19/06/19 P F906

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"6.1","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: