IBM Support

PH08329: COBOL COMPILER USING OPT(2) ISSUES IGYCB7104-U FAILED ASSERTION ON ... COBOLUSEBEFORESET.CPP:545

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • USERS AFFECTED: Users of Enterprise COBOL Vx.x compiling
    programs at OPT(1|2) and INITCHECK
    containing tables that have VALUE clauses
    
    PROBLEM DESCRIPTION: Compiler abend with message
    MSGIGYCB7104-U Internal error while
    compiling function 'XXXXX'. Failed
    assertion
    on../../trwcode/optimizer/analyses/COB
    O
    LUseBeforeSet.cpp:545. Compilation
    terminated.
    
    RECOMMENDATION TO CUSTOMER: Apply the provided PTF
    
    PROBLEM SUMMARY: The compiler was attempting to see if a group
    item was
    initialized due to all its component items being initialized,
    but it was not considering tables that were initialized through
    a VALUE clause, causing the compiler's internal state to become
    inaccurate.
    
    CONCLUSION: The compiler was fixed to consider tables
    initialized through a
    value clause and have a correct internal state.
    

Local fix

  • Compile at OPT(0) or with NOINITCHECK
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V5.2 compiling     *
    *                 programs at OPT(1|2) and INITCHECK           *
    *                 containing tables that have VALUE clauses.   *
    ****************************************************************
    * PROBLEM DESCRIPTION: Compiler abend with message             *
    *                      MSGIGYCB7104-U Internal error while     *
    *                      compiling function 'XXXXX'. Failed      *
    *                      assertion                               *
    *                      on../../trwcode/optimizer/analyses/COB  *
    *                      OLUseBeforeSet.cpp:545. Compilation     *
    *                      terminated.                             *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF                       *
    ****************************************************************
    The compiler was attempting to see if a group item was
    initialized due to all its component items being initialized,
    but it was not considering tables that were initialized through
    a VALUE clause, causing the compiler's internal state to become
    inaccurate.
    

Problem conclusion

  • The compiler was fixed to consider tables initialized through a
    value clause and have a correct internal state.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH08329

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655W3200

  • Reported release

    520

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-02-08

  • Closed date

    2019-02-20

  • Last modified date

    2019-03-01

  • APAR is sysrouted FROM one or more of the following:

    PH06255

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCBE   IGYCCBE  IGYCCICS IGYCCSRV IGYCDGEN IGYCDIAG
    IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4 IGYCEN$5
    IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT IGYCJA$0
    IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8 IGYCJA$D
    IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0 IGYCLVL1
    IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN IGYCRCTL
    IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD IGYCUE$0
    IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8 IGYCUE$D
    IGYCUE$R IGYCXREF IGYECWI  IGYMSGE  IGYMSGK  IGYMSGT
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655W3200

Applicable component levels

  • R520 PSY UI61388

       UP19/02/23 P F902

  • R521 PSY UI61389

       UP19/02/26 P F902

  • R522 PSY UI61390

       UP19/02/26 P F902

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"520","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
01 March 2019