PH07210: THE CBL COMPILER MAY TRUNCATE THE BINARY VALUE TO MATCH ITS PICTURE CLAUSE BEFORE A COMPARISON.

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • The compiler was assuming that binary data would be valid and
    wouldn't exceed the picture clause, so it could be truncated
    before a comparison without affecting the results.
    
    The compiler was fixed to provide compatibility with COBOL V4.2
    and earlier, even when invalid data was used, by not truncating
    binary data before a comparison any more than COBOL V4.2 would
    truncate (e.g. to match the size of the COMP-3 or USAGE DISPLAY
    data being compared against).
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: Users of Enterprise COBOL V6.2 using         *
    *                 TRUNC(STD|OPT) comparing BINARY/COMP/COMP-4  *
    *                 data items to USAGE DISPLAY or COMP-3 data   *
    *                 items where the binary data item contains a  *
    *                 value larger than its picture clause and     *
    *                 the COMP-3 or USAGE DISPLAY data item has    *
    *                 more digits specified in its picture clause  *
    *                 than the binary data item.                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: The compiler may truncate the binary    *
    *                      value to match its picture clause       *
    *                      before a comparison. If the data item   *
    *                      contains a value exceeding its picture  *
    *                      clause, the comparison may have a       *
    *                      different result than Enterprise COBOL  *
    *                      V4.2 and earlier.                       *
    ****************************************************************
    * RECOMMENDATION: Apply the provided PTF and use ZONEDATA(MIG) *
    *                 if you previously used NUMPROC(MIG) in       *
    *                 COBOL V4.2 and earlier, or ZONEDATA(NOPFD)   *
    *                 otherwise.                                   *
    ****************************************************************
    The compiler was assuming that binary data would be valid and
    wouldn't exceed the picture clause, so it could be truncated
    before a comparison without affecting the results.
    

Problem conclusion

  • The compiler was fixed to provide compatibility with COBOL V4.2
    and earlier, even when invalid data was used, by not truncating
    binary data before a comparison any more than COBOL V4.2 would
    truncate (e.g. to match the size of the COMP-3 or USAGE DISPLAY
    data being compared against).
    

Temporary fix

Comments

APAR Information

  • APAR number

    PH07210

  • Reported component name

    ENT COBOL FOR Z

  • Reported component ID

    5655EC600

  • Reported release

    620

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2019-01-11

  • Closed date

    2019-01-14

  • Last modified date

    2019-02-02

  • APAR is sysrouted FROM one or more of the following:

    PH04979

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • IGY8RWTU IGYCASMB IGYCCBE  IGYCCCRT IGYCCICS IGYCCSRV IGYCDGEN
    IGYCDIAG IGYCDMAP IGYCEN$0 IGYCEN$1 IGYCEN$2 IGYCEN$3 IGYCEN$4
    IGYCEN$5 IGYCEN$8 IGYCEN$D IGYCEN$R IGYCFGEN IGYCFREE IGYCINIT
    IGYCJA$0 IGYCJA$1 IGYCJA$2 IGYCJA$3 IGYCJA$4 IGYCJA$5 IGYCJA$8
    IGYCJA$D IGYCJA$R IGYCLIBH IGYCLIBO IGYCLIBR IGYCLSTR IGYCLVL0
    IGYCLVL1 IGYCLVL2 IGYCLVL3 IGYCLVL8 IGYCMALL IGYCOSCN IGYCPGEN
    IGYCRCTL IGYCRDPR IGYCRDSC IGYCREAL IGYCRWT  IGYCSCAN IGYCSIMD
    IGYCUE$0 IGYCUE$1 IGYCUE$2 IGYCUE$3 IGYCUE$4 IGYCUE$5 IGYCUE$8
    IGYCUE$D IGYCUE$R IGYCXREF IGYDRV   IGYEQCWI IGYMSGE  IGYMSGK
    IGYMSGT  IGYQCBE  IGYZQDRV IGYZQENU IGYZQJPN
    

Fix information

  • Fixed component name

    ENT COBOL FOR Z

  • Fixed component ID

    5655EC600

Applicable component levels

  • R620 PSY UI60666

       UP19/01/30 P F901

  • R621 PSY UI60667

       UP19/01/30 P F901

  • R622 PSY UI60668

       UP19/01/30 P F901

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SS6SG3","label":"Enterprise COBOL for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"620","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]