Error description

  • Client noticed the following messages after they IPL'd their
    z/OS system running on z/VM and the system was trying to
    establish an outbound connection:
    
    AOF334I UNABLE TO RECEIVE THE OUTPUT FROM THE REQUESTED SYSTEM
    KR2D1 - FROM=AUA1
    
    DWO369I CORRWAIT STAGE (2) HAD RETURN CODE 8.
    
    The client tried using the AAO AOFRMTCMDWAIT Read/Write
    variable (documented in the Customizing and Programming
    manual), but this did not help.
    Investigation confirmed the (#5 + 2 = 7 seconds) time out was
    hard coded in INGR1IGT
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All SA z/OS V3R3, SA z/OS V3R4 and           *
    *                 SA z/OS V3R5 customers using the DISPGW      *
    *                 command.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: When processing GATEWAY connections,    *
    *                      SA z/OS should make allowance for       *
    *                      slower systems in the enterprise.       *
    *                      This will make sure that the DISPGW     *
    *                      display is correct and msgING025I is    *
    *                      issued as expected when communication   *
    *                      has been established with remote        *
    *                      systems.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SA z/OS should increase the wait time when processing GATEWAY
    connections.
    This of course may increase the total execution time of the
    GATEWAY connection processing when some systems cannot be
    reached.
    

Problem conclusion

  • REXX part INGR1IGT has been modified to allow for a longer
    maximum wait time when processing GATEWAY connections with
    remote systems.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA46975

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-01-23

  • Closed date

    2015-03-13

  • Last modified date

    2015-04-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA76565 UA76566 UA76567

Modules/Macros

  • INGR1IGT
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R330 PSY UA76565

       UP15/03/20 P F503

  • R340 PSY UA76566

       UP15/03/20 P F503

  • R350 PSY UA76567

       UP15/03/20 P F503

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSWRCJ","label":"IBM Tivoli System Automation for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"330","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: