Error description
KFWITM354E message is issued when attempting to retrieve CCC Logs historical data. The following messages are also issued in the TEMS RAS1 trace log: (50B75092.0000-4:kdspbcom.c,1044,"GetFuncVector") Unable to load probe KRAHSLOC, status = 5 (50B75092.0001-4:kdspmou2.c,388,"PM1_BuildTable") Cannot create locator object, status = 5 (50B75092.0002-4:kdspmou1.c,721,"PM1_CompilerOutput") Cannot build table object, status = 5 (50B75092.0003-4:kdspmcv.c,1063,"CreateTable") VPM1_Output Failed status: 5 (50B75092.0004-4:kdspmcv.c,1064,"CreateTable") Compiler output error, status = 5 (50B75092.0005-4:kdsvws1.c,1371,"CreateServerView") Bad status from VPM1_CreateTable, 5 (50B75092.0006-4:kdspac1.c,2006,"VPA1_CreateRequest") Create request failed with return code 5 RECREATE INSTRUCTIONS: Enable historical data collection for the CCC Logs. eg. Situation Status Log. Issue the following SQL: SELECT TSITSTSH.WRITETIME, TSITSTSH.ORIGINNODE, TSITSTSH.NODE, TSITSTSH.LCLTMSTMP, TSITSTSH.DELTASTAT, TSITSTSH.SITNAME, TSITSTSH.ATOMIZE, TSITSTSH.GBLTMSTMP, TSITSTSH.TYPE FROM O4SRV.TSITSTSH AT( '*HUB' ) HISTORY() WHERE TSITSTSH.WRITETIME >= '1121028171522000' AND TSITSTSH.WRITETIME <= '1121029171522000'; The following messages will be issued to the TEMS RAS1 trace log: (50B750A9.0000-14:kdspbcom.c,1044,"GetFuncVector") Unable to load probe KRAHSLOC, status = 5 (50B750A9.0001-14:kdspmou2.c,388,"PM1_BuildTable") Cannot create locator object, status = 5 (50B750A9.0002-14:kdspmou1.c,721,"PM1_CompilerOutput") Cannot build table object, status = 5 (50B750A9.0003-14:kdspmcv.c,1063,"CreateTable") VPM1_Output Failed status: 5 (50B750A9.0004-14:kdspmcv.c,1064,"CreateTable") Compiler output error, status = 5 (50B750A9.0005-14:kdsvws1.c,1371,"CreateServerView") Bad status from VPM1_CreateTable, 5 (50B750A9.0006-14:kdspac1.c,2006,"VPA1_CreateRequest") Create request failed with return code 5
Local fix
Provided a corrected kms.cat file by adding KRANDREG to the "H" record.
Problem summary
**************************************************************** * USERS AFFECTED: All TEMS users. * **************************************************************** * PROBLEM DESCRIPTION: THE USER IS RETURNED ERROR KFWITM354E * * WHEN ATTEMPTING TO QUERY HISTORY FOR * * CCC LOGS (SITUATION STATUS LOG). * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** The user is returned error KFWITM354E when attempting to query History for CCC Logs (Situation Status Log). The monitoring server fails to load the probe for Local History. As a result, any attempts to exercise SQL queries against Local History file TSITSTSH will fail with the following error message: KFWITM217E Request error SQL1_CreateRequest failed rc=5 User will also find following series of trace messages in TEMS RAS1 trace log : kdspbcom.c,1044,"GetFuncVector"} Unable to load probe KRAHSLOC, status = 5 kdspbcom.c,1048,"GetFuncVector"} Exit: 0x5 kdspmou2.c,388,"PM1_BuildTable"} Cannot create locator object, status = 5 kdspmou1.c,721,"PM1_CompilerOutput"} Cannot build table object, status = 5 kdspmcv.c,1063,"CreateTable"} VPM1_Output Failed status: 5 kdspmcv.c,1064,"CreateTable"} Compiler output error, status = 5 kdsvws1.c,1371,"CreateServerView"} Bad status from VPM1_CreateTable, 5 kdspac1.c,2006,"VPA1_CreateRequest"} Create request failed with return code 5
Problem conclusion
Correction was made to appropriate catalog file.
Temporary fix
Comments
APAR Information
APAR number
OA43270
Reported component name
MGMT SERVER DS
Reported component ID
5608A2800
Reported release
630
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-09-06
Closed date
2013-09-09
Last modified date
2013-10-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Modules/Macros
KMSCAT
Fix information
Fixed component name
MGMT SERVER DS
Fixed component ID
5608A2800
Applicable component levels
R630 PSY UA70678
UP13/09/19 P F309
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSRJ5K","label":"Tivoli Management Server for Distributed Systems on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"630","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]
Document Information
Modified date:
03 October 2013