**************************************************************** * USERS AFFECTED: All IBM Automation Control for z/OS V1R1 * * customers. * **************************************************************** * PROBLEM DESCRIPTION: see below * **************************************************************** * RECOMMENDATION: * **************************************************************** o Existing Event Filters for a closed target system are not removed when appropriate. o SA-BCPii HW validation performance should be improved. o Excessive time required to connect to processor using the SA-BCPii. o Helpful diagnostic service information added to 0B100119 condition failure reports. o NetView termination may hang due to incorrect SA-BCPii routine ESTAEX. o Batch Command Interface fails for jobnames with less than 8 characters. This can result in messages: INGPC010I INGICRPC is unable to perform function AOF_PPI_SEND, PPI_id=INGRCRCV INGPC011I INGPAUTH failed RC=185 Invalid handle
Problem conclusion
Temporary fix
Comments
ISQSNMPC, ISQTCPI and ISQGCQRY were changed to correct the CNMEPING result checking. Each time clist INGRX809 is executing as part of the HW validation for processor LPARs, the image status EXCEPTIONS was handled as an extraordinary tentative condition, with GETIINFO calls in a loop. In the meantime, we are convinced this special handling is no longer required to satisfy the HW validation minimum requirements. Consequently, the code block is removed, which will slightly improve the overall INGRX809 performance. Clist INGRX830 was changed to no longer use the SHRWAIT option to obtain the required processing lock. Now, SHR without a wait is used and in case the lock cannot be obtained as requested, INGRX830 reschedules itself using a NV timer. This frees up the affected NetView task to accept other work, instead of waiting in INGRX830 until the lock (HWVALIDATION) is available for an undetermined period of time, blocking all other work. SINGMOD3 module HSAPHARI was extended to provide additional sense information in sub-function FIND_HSE. Module HSAPHSPT, subroutine CLEAN_UP was changed to not go in an ECB wait if the module's ESTAEX has control. INGPAUTH was changed to make sure that the Batch Command Interface does not fail for jobnames with less than 8 characters. The comments above also include the code changes of SA z/OS APARs OA43108, OA42878 and OA43617.
APAR Information
APAR number
OA43045
Reported component name
AUTO CONTROL FO
Reported component ID
5698LSA00
Reported release
110
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2013-08-08
Closed date
2014-02-06
Last modified date
2014-03-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA72296
Modules/Macros
HSAPHARI HSAPHSPT INGPAUTH INGRX809 INGRX830 ISQGCQRY ISQSNMPC ISQTCPI
Fix information
Fixed component name
AUTO CONTROL FO
Fixed component ID
5698LSA00
Applicable component levels
R110 PSY UA72296
UP14/02/14 P F402
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
14 December 2020