OA41931: INCORRECT METRIC ID FOR LCSFRAV EXCEPTION IN RMFDEFLT MEMBER.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The LCSFRAV exception defined in the RMFDEFLT member shipped
    with Tivoli Event Pump has a metric ID of 8D0050, which is
    incorrect. Implementing the RMF data feed using this member will
    result in the following events being seen containing the
    GPM0626I error:
    
    EIF0301 : TEC EVENT DATA FOLLOWS
    TEC_GENERIC;source=MANULIFE.MANUMKM8;name_value_pa
    irs=■'_FORMAT=02','_ACTION=21','_F00=2013041107:15
    :00.638461','_F01=SYSJ14513','_F37=ERROR','_F36=LC
    SFRAV','_F02=OS','_F04=0000120006','_F42=E','_F38=
    0.0','_F39=;SYSPLEX(PRODPLX1) TIME(20130411071500)
     RESOURCE(SYSJ,*,CENTRAL_STORAGE);?','_F40=04 GPM0
    626I The metric 008D0050 is not defined for resour
    ce type CENTRAL_STORAGE and work scope ''G'''~;END
    
    
    The correct metric ID for LCSFRAV is 8D0380.
    

Local fix

  • Manually edit RMFDEFLT member and alter the LCSFRAV entry from
    this:
    
    DEFAULT LCSFRAV,  %name%, *,      CENTRAL_STORAGE,  NULL, NULL,
    G, 8D0050
            LT, 5,   Low available frames,       100, 0
    
    to this:
    
    DEFAULT LCSFRAV,  %name%, *,      CENTRAL_STORAGE,  NULL, NULL,
    G, 8D0380
            LT, 5,   Low available frames,       100, 0
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli Event Pump for z/OS users using   *
    *                 RMF feed.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION: The LCSFRAV exception defined in the    *
    *                      RMFDEFLT member shipped with Tivoli     *
    *                      Event Pump has a metric ID of 8D0050,   *
    *                      which is incorrect. Implementing the    *
    *                      RMF data feed using this member will    *
    *                      result in the following events being    *
    *                      seen containing the GPM0626I error:     *
    *                                                              *
    *                      EIF0301 : TEC EVENT DATA FOLLOWS        *
    *                      TEC_GENERIC;source=MANULIFE.MANUMKM8;n  *
    *                      ame_value_pairs= '_FORMAT=02','_ACTION  *
    *                      =21','_F00=2013041107:15:00.638461','_  *
    *                      F01=SYSJ14513','_F37=ERROR','_F36=LCSF  *
    *                      RAV','_F02=OS','_F04=0000120006','_F42  *
    *                      =E','_F38=0.0','_F39=;SYSPLEX(PRODPLX1  *
    *                      ) TIME(20130411071500) RESOURCE(SYSJ,*  *
    *                      ,CENTRAL_STORAGE);?','_F40=04 GPM0626I  *
    *                      The metric 008D0050 is not defined for  *
    *                      resource type CENTRAL_STORAGE and work  *
    *                      scope ''G''' ;END                       *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    ****************************************************************
    The correct metric ID for LCSFRAV is 8D0380.
    

Problem conclusion

  • Exception definitions for RMF have been corrected.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA41931

  • Reported component name

    EVENT PUMP FOR

  • Reported component ID

    5698B3400

  • Reported release

    422

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2013-04-12

  • Closed date

    2013-05-27

  • Last modified date

    2013-06-03

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA69263

Modules/Macros

  • GPZRMFCU GPZRMFDE
    

Fix information

  • Fixed component name

    EVENT PUMP FOR

  • Fixed component ID

    5698B3400

Applicable component levels

  • R422 PSY UA69263

       UP13/06/01 P F305

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page: