Fixes are available
APAR status
Closed as program error.
Error description
Abend S0C4 occurs during TEMS shutdown. The failure is the result of an incorrectly coded TRC1_NoteError() statement in kdsmacmd.c'c ShutdownCommand() function. RECREATE INSTRUCTIONS: N/A
Local fix
A ++APAR can be provided if required for this abend during shutdown.
Problem summary
**************************************************************** * USERS AFFECTED: All TEMS users. * **************************************************************** * PROBLEM DESCRIPTION: S0C4 ABEND DURING SHUTDOWN OF THE * * TIVOLI ENTERPRISE MANAGEMENT SERVER. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** ABEND S0C4 occurs during shutdown of the Tivoli Enterprise Management Server.
Problem conclusion
The code has been updated to prevent the ABEND.
Temporary fix
Comments
APAR Information
APAR number
OA41854
Reported component name
MGMT SERVER DS
Reported component ID
5608A2800
Reported release
623
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2013-04-03
Closed date
2013-06-09
Last modified date
2014-02-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
MGMT SERVER DS
Fixed component ID
5608A2800
Applicable component levels
R623 PSY UA71029
UP13/10/23 P F310
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU029","label":"Software"},"Product":{"code":"SSRJ5K","label":"Tivoli Management Server for Distributed Systems on z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"623"}]
Document Information
Modified date: