A fix is available
APAR status
Closed as program error.
Error description
DSECT changes referencing the OMEGAMON XE IMS Connect workarea may cause an abend with a S0C4 in module KIPICP00+x'45A'. This is due to two modules that reference this common workarea did not get regenerated as part of APAR OA39673 PTF's UA67243(V420) and UA67244(V520) during PTF build.
Local fix
N/A
Problem summary
**************************************************************** * USERS AFFECTED: All OMEGAMON XE for IMS on z/OS for V4.2.0 * * And V5.1.0 using IMS Connect. * **************************************************************** * PROBLEM DESCRIPTION: S0C4 may occur in KIPICP00+x'45A' after * * UA67243 (V4.2.0) or UA67244 (V5.1.0) * **************************************************************** * RECOMMENDATION: Apply this PTF. * **************************************************************** DSECT changes referencing the XE IMS Connect workarea may cause a S0C4 abend in module KIPICP00+x'45A'. This is due to two modules that reference this common workarea that did not get regenerated as part of APAR OA39673.
Problem conclusion
PTF packaging has been updated to include all modules that reference the XE IMS Connect common workarea.
Temporary fix
***************************************** * HIPER * SMP RESTORE UA67243 (V420) OR * * * UA67244 (V510). * *****************************************
Comments
APAR Information
APAR number
OA41455
Reported component name
OM XE FOR IMS Z
Reported component ID
5698A3900
Reported release
420
Status
CLOSED PER
PE
YesPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2013-02-18
Closed date
2013-02-22
Last modified date
2013-05-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA68121 UA68122
Modules/Macros
KIPC8000 KIPC8100 KIPC8200 KIPC8300 KIPC8400 KIPICA00 KIPICB00 KIPICI00 KIPICP00 KIPICX00
Fix information
Fixed component name
OM XE FOR IMS Z
Fixed component ID
5698A3900
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXS8U","label":"Tivoli OMEGAMON XE for IMS on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: