A fix is available
APAR status
Closed as program error.
Error description
Abend 0C9 in KXDWLCON KXDGTLK
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All OMEGAMON XE ON Z/OS users. * **************************************************************** * PROBLEM DESCRIPTION: Abend 0C9 in the TEMS in * * KXDWLCON.KXDGTLK routine. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** The code that calculates specialty processor cpu utilization can overflow when a short interval occurs.
Problem conclusion
Modified the code to check for divide overflow conditions before completing the calculation.
Temporary fix
Comments
**** PE13/11/20 FIX IN ERROR. SEE APAR OA43297 FOR DESCRIPTION
APAR Information
APAR number
OA41065
Reported component name
OMEG XE ON Z/OS
Reported component ID
5698A5900
Reported release
420
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-12-17
Closed date
2013-02-15
Last modified date
2013-11-20
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA68046 UA68047
Modules/Macros
KXDWLCON
Fix information
Fixed component name
OMEG XE ON Z/OS
Fixed component ID
5698A5900
Applicable component levels
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SS2JNN","label":"Tivoli OMEGAMON XE on z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"420","Edition":"","Line of Business":{"code":"LOB17","label":"Mainframe TPS"}}]
Document Information
Modified date: