OA40794: MSGAOF200I CMD INGRX806 FAILED. RECEIVED RC 1 FROM INGHWCMD. SA34: ProcOps msgIRX0043I Rexx error - Routine not found

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • MsgAOF200I COMMAND INGRX806 FAILED. RECEIVED RETURN CODE 1
    FROM INGHWCMD at SA z/OS initialization.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All System Automation for z/OS customers of  *
    *                 the releases V3.3 and V3.4, using the BCP    *
    *                 Internal Interface function of the product.  *
    *                 For V3.4 only: All customers using the       *
    *                 Processor Operations function of the         *
    *                 product.                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION: At SA z/OS initialization, the BCP      *
    *                      Internal Interface initialization may   *
    *                      end with msgAOF200I COMMAND INGRX806    *
    *                      FAILED. RECEIVED RETURN CODE 1 FROM     *
    *                      INGHWCMD.                               *
    *                                                              *
    *                      SA34 only: Internal ProcOps routines    *
    *                      may end with msgIRX0043I Rexx error:    *
    *                      Routine not found.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    SA-BCPii initialization routine INGRX806 reports RC 1 from
    INGHWCMD. SA34 only: Internal ProcOps routines get Rexx error
    'Routine not found'.
    

Problem conclusion

  • Module INGRX810/INGHWCMD was changed. Internal checking for the
    SCLP ET32 interface availability was changed to retry checking
    in a loop to give the interface enough time to get initialized
    before it is used.
    
    SA34 only:
    
    Rexx macro ISQC0001 was changed to no longer use the macro form
    of AOFMSG. The include-macro is used in:
    
      ISQ$NMC
      ISQGCCC
      ISQGCMD
      ISQGCQRY
      ISQGIOK
      ISQGSQRY
      ISQGTCL
      ISQGTII
      ISQSNMPS
      ISQTCPS
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA40794

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    330

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-12

  • Closed date

    2012-11-21

  • Last modified date

    2012-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA67294 UA67295

Modules/Macros

  •    INGRX810 ISQ$NMC  ISQGCCC  ISQGCMD  ISQGCQRY
    ISQGIOK  ISQGSQRY ISQGTCL  ISQGTII  ISQSNMPS ISQTCPS
    

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R330 PSY UA67294

       UP12/11/24 P F211

  • R340 PSY UA67295

       UP12/11/24 P F211

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli System Automation for z/OS

Software version:

330

Reference #:

OA40794

Modified date:

2012-12-04

Translate my page

Machine Translation

Content navigation