OA40744: KAUWLINK RETURN CODE 8 WHEN STARTING A TCPIP LINK RESOURCE

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • An RCF INIT is done to start a TCPIP link from the IRM to SA
    IOM.
    
    'EX KAUWLINK sysid' is the START command for the resource.
    
    The RCF INIT fails, but the only messages seen in the log are:
    
        !AOP0425 EX KAUWLINK
        !AOP0093 EXEC RETURN CODE 8; AOENDCC IS 0
    
    The problem is that an internal "WAIT WTO" command being issued
    by the KAUWLINK exec exceeds the maximum command length of 255
    for an AF/Operator command.
    

Local fix

  • Shorten the resource name to less than 8 characters.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All AF/INTEGRATED RESOURCE MANAGER users.    *
    ****************************************************************
    * PROBLEM DESCRIPTION: An RCF INIT is done to start a TCPIP    *
    *                      link from the IRM to SA IOM.  'EX       *
    *                      KAUWLINK sysid' is the START command    *
    *                      for the resource.  The RCF INIT fails,  *
    *                      but the only messages seen in the log   *
    *                      are:  !AOP0425 EX KAUWLINK !AOP0093     *
    *                      EXEC RETURN CODE 8; AOENDCC IS 0  The   *
    *                      problem is that an internal "WAIT WTO"  *
    *                      command being issued by the KAUWLINK    *
    *                      exec exceeds the maximum command length *
    *                      of 255 for an AF/Operator command.      *
    ****************************************************************
    * RECOMMENDATION: Apply the PTF.                               *
    An RCF INIT is done to start a TCPIP link from the IRM to SA
    IOM.  'EX KAUWLINK sysid' is the START command for the resource.
    The RCF INIT fails, but the only messages seen in the log are:
    !AOP0425 EX KAUWLINK !AOP0093 EXEC RETURN CODE 8; AOENDCC IS 0
    The problem is that an internal "WAIT WTO" command being issued
    by the KAUWLINK exec exceeds the maximum command length of 255
    for an AF/Operator command.
    

Problem conclusion

  • Reduce length of Link Define statement.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA40744

  • Reported component name

    AF IRM TOOL

  • Reported component ID

    5608AFIRM

  • Reported release

    500

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-11-07

  • Closed date

    2012-11-14

  • Last modified date

    2012-12-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA67209 UA67210

Modules/Macros

  •    KAUWLINK
    

Fix information

  • Fixed component name

    AF IRM TOOL

  • Fixed component ID

    5608AFIRM

Applicable component levels

  • R500 PSY UA67209

       UP12/11/28 P F211

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Document information


More support for:

Tivoli AF/Integrated Resource Manager

Software version:

500

Reference #:

OA40744

Modified date:

2012-12-04

Translate my page

Machine Translation

Content navigation