Error description
Tivoli Event Pump supports monitoring of the JOBLOG messages starting release 4.2.2. Several customers request enhance it with support of multiple-line messages in JOBLOG.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Tivoli Event Pump users using JOBLOG * * monitoring. * **************************************************************** * PROBLEM DESCRIPTION: Add multiple-line messages support to * * JOBLOG data source. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** Applications can create JOBLOG messages which contain several logically connected strings. E.g. DFHLG0746 is two line message in the CICS DFHCXRF DD: DFHZC5966 I 01/17/2012 06:12:05 DFHF32 RESTORE started for ... DFHLG0746 01/17/2012 06:12:05 DFHF32 System log scan trim ... secondary logstream block id X'0000000000000000'. Meanwhile JES spool data set is a sequential data set and applications can read/write it only record by record. So there is no way to identify that any of the records are logically connected and belongs to the multi-line message. This APAR treats logically connected strings as pseudo multiple-line message and processes them based on new parameter specifying number of lines to be processed.
Problem conclusion
Temporary fix
Comments
New LINE_NUMBER parameter has been added to ZEVENT statement which allows customer to define message and event processing. New parameter allows customer to specify number of lines to be processed. The following information should be added to the Chapter 7. Monitor file (GTMMON DD statement) of Configuration Reference (SC27-4041-00): ZEVENT statement The ZEVENT statement defines message and event processing. ZEVENT entries are defined to create events for exceptions and to create events to clear these exceptions. ZEVENT zevent_entry MASK mask --- OPTIONAL INFORMATION YES | NO --- OPTIONAL INTERVAL resolution_interval --- OPTIONAL MESSAGE msg_text --- OPTIONAL EVENTID event_id --- OPTIONAL SEVERITY UP |CL|IN|WA|MI|MA|DO|CR --- OPTIONAL RESOURCE resource_name --- OPTIONAL RESOURCE_TYPE resource_type --- OPTIONAL RESOURCE2 subresource --- OPTIONAL USERn user_event_slot --- OPTIONAL | LINE_NUMBER JES_lines_number --- OPTIONAL END . . . Table 9. ZEVENT entries +---------------+-------+------------+------+---------------+ |EVENT slot name|ZEVENT |Substitution|Field |Explanation | | | |Supported |number| | +---------------+-------+------------+------+---------------+ |MASK |YES | |N/A |This value is | | | | | |... | | | | | | | | | | | | | +---------------+-------+------------+------+---------------+ | | | | | | | . . . | | | | | | | | | | | | | | | | | +---------------+-------+------------+------+---------------+ | |LINE_NUMBER |YES | |N/A |Number of lines| | | | | |to read | +---------------+-------+------------+------+---------------+ | | | | | | | . . . | | | | | | | | | | | | | | | | | +---------------+-------+------------+------+---------------+ The following messages should be added to the Tivoli Event Pump for z/OS version 4.2.2, Message Reference (GC27-2310-05): GPZ3070W INCORRECT DECIMAL NUMBER value SPECIFIED IN LINE_NUMBER PARAMETER ON RECORD record Explanation: The value of ZEVENT LINE_NUMBER parameter should be 0-99. Message variables : value - LINE_NUMBER parameter value record - zevent entry name System action: Processing continues Administrator response: Correct the ZEVENT statement and register the monitoring. GPZ3071W LINE_NUMBER value SPECIFIED ON RECORD record WITH TYPE type. BUT IT APPLIES ONLY FOR TYPE JES Explanation: The LINE_NUMBER parameter is applicable for ZEVENT entries with TYPE JES. Message variables : value - LINE_NUMBER parameter value record - ZEVENT entry name type - ZEVENT entry type System action: Processing continues Administrator response: Correct the ZEVENT statement and register the monitoring.
APAR Information
APAR number
OA39402
Reported component name
EVENT PUMP FOR
Reported component ID
5698B3400
Reported release
422
Status
CLOSED UR1
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2012-04-24
Closed date
2012-12-03
Last modified date
2013-04-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA67377
Modules/Macros
GPZJLMON GPZMSGTB GPZREAD3 GTMAOPD0 GTMAOPD1 GTMAOPD2 GTMAOPD3 GTMRX038
SC27404100 | GC27231005 |
Fix information
Fixed component name
EVENT PUMP FOR
Fixed component ID
5698B3400
Applicable component levels
R422 PSY UA67377
UP13/03/20 P F303
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXTW7","label":"Tivoli Event Pump for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"","label":""}}]