IBM Support

OA39339: TIVOLI EVENT PUMP CUSTOMIZER FIXES

A fix is available

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Customizer might fail as follow:
    
    IEA995I SYMPTOM DUMP OUTPUT  636
    
    SYSTEM COMPLETION CODE=0C4  REASON CODE=00000011
     TIME=03.50.19  SEQ=04983  CPU=0000  ASID=00B1
     PSW AT TIME OF ERROR  078D2000   8E11D222  ILC 6  INTC 11
       ACTIVE LOAD MODULE           ADDRESS=0E116CB8
    OFFSET=0000656A
       NAME=GPZAOPC1
       DATA AT PSW  0E11D21C - B7E85850  9B84D506  4000BB28
       GR 0: 0DFA9C6E   1: 00000003
          2: 0DFD2927   3: 0DFD2927
          4: 0E12EFFA   5: 0DFA9340
          6: 00000006   7: 0DFD2E50
          8: 0D9BF8F0   9: 0DFA93C8
          A: 0D9BF4B8   B: 0E11CD68
          C: 0E11DD68   D: 0DFD2EA4
          E: 0DFA9BAC   F: 0DFD2927
     END OF SYMPTOM DUMP
    
    Also user specified field might get incorrect number in event,
    e.g. instead of USER90, USER91 and USER92 you might get fileds
    F50649, F16612 and F58053 in event:
    
     TBSMV3_SOURCE390;source=NET1.TVT5104;name_value_pa
     irs=■'_FORMAT=30','_ACTION=05','_F00=2012041603:53
     :58.089791','_F01=510412','_F10=5104','_F11=NET1.T
     VT5104','_F12=EVPMPLEX','_F13=GRS','_F14=STC','_F1
     5=ISG343I','_F16=03.53.57 GRS STATUS 722 LATCH DIS
     PLAY FOR JOB NAME NO LATCH CONTENTION EXISTS','_F1
     7=ISG343I 03.53.57 GRS STATUS 722 LATCH DISPLAY FO
     R JOB NAME NO LATCH CONTENTION EXISTS','_F18=TEST'
     ,'_F19=0','_F21=GRS','_F22=STC','_F50649=03.53.57'
     ,'_F16612=722 NO LATCH CONTENTION EXISTS','_F58053
     =NAME';END
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All Tivoli Event Pump users.                 *
    ****************************************************************
    * PROBLEM DESCRIPTION: 1. Customizer might fail with S0C4 if   *
    *                         ZEVENT user fields USER90-USER139    *
    *                         have been specified:                 *
    *                                                              *
    *                         IEA995I SYMPTOM DUMP OUTPUT  636     *
    *                                                              *
    *                         SYSTEM COMPLETION CODE=0C4  REASON   *
    *                         CODE=00000011                        *
    *                          TIME=03.50.19  SEQ=04983  CPU=0000  *
    *                          ASID=00B1                           *
    *                          PSW AT TIME OF ERROR  078D2000      *
    *                          8E11D222  ILC 6  INTC 11            *
    *                            ACTIVE LOAD MODULE                *
    *                            ADDRESS=0E116CB8 OFFSET=0000656A  *
    *                            NAME=GPZAOPC1                     *
    *                            DATA AT PSW  0E11D21C - B7E85850  *
    *                            9B84D506  4000BB28                *
    *                            GR 0: 0DFA9C6E   1: 00000003      *
    *                               2: 0DFD2927   3: 0DFD2927      *
    *                               4: 0E12EFFA   5: 0DFA9340      *
    *                               6: 00000006   7: 0DFD2E50      *
    *                               8: 0D9BF8F0   9: 0DFA93C8      *
    *                               A: 0D9BF4B8   B: 0E11CD68      *
    *                               C: 0E11DD68   D: 0DFD2EA4      *
    *                               E: 0DFA9BAC   F: 0DFD2927      *
    *                          END OF SYMPTOM DUMP                 *
    *                                                              *
    *                      2. Customizer ZEVENT user specified     *
    *                         fields USER90-USER139 might get      *
    *                         incorrect number in the EIF event,   *
    *                         e.g. for USER90-USER92 you might get *
    *                         fileds F50649, F16612 and F58053     *
    *                         instead of F90-F92:                  *
    *                                                              *
    *                         TBSMV3_SOURCE390;source=NET1.TVT5104 *
    *                         ;name_value_pairs='_FORMAT=30','_ACT *
    *                         ION=05','_F00=2012041603:53:58.08979 *
    *                         1','_F01=510412','_F10=5104','_F11=N *
    *                         ET1.TVT5104','_F12=EVPMPLEX','_F13=G *
    *                         RS','_F14=STC','_F15=ISG343I','_F16= *
    *                         03.53.57 GRS STATUS 722 LATCH DISPLA *
    *                         Y FOR JOB NAME NO LATCH CONTENTION E *
    *                         XISTS','_F17=ISG343I 03.53.57 GRS ST *
    *                         ATUS 722 LATCH DISPLAY FOR JOB NAME  *
    *                         NO LATCH CONTENTION EXISTS','_F18=TE *
    *                         ST','_F19=0','_F21=GRS','_F22=STC',' *
    *                         _F50649=03.53.57','_F16612=722 NO LA *
    *                         TCH CONTENTION EXISTS','_F58053=NAME *
    *                         ';END                                *
    *                                                              *
    *                      3. Usage of ZEVENT MESSAGE keyword for  *
    *                         long data (longer 256 bytes) can     *
    *                         result in incorrect value in event   *
    *                         field F17, e.g                       *
    *                                                              *
    *                         TBSMV3_SOURCE390;source=NET1.TVT5104 *
    *                         ;name_value_pairs= '_FORMAT=30','_AC *
    *                         TION=03','_F00=2012052901:51:49.2602 *
    *                         63','_F01=510424','_F10=5104','_F11= *
    *                         NET1.TVT5104','_F12=EVPMPLEX','_F13= *
    *                         MBAVBELX','_F14=BATC','_F15=+IEE200I *
    *                         ','_F16=13.51.18 DISPLAY ASM TYPE    *
    *                         FULL STAT   DEV  DATASET NAME PLPA   *
    *                         37%   OK  310F  PAGE.BT27.PLPA COMMO *
    *                         N     0%   OK  310F  PAGE.BT27.COMMO *
    *                         N1 LOCAL      2%   OK  320F  PAGE.BT *
    *                         27.LOCAL1 LOCAL      2%   OK  330F   *
    *                         PAGE.BT27.LOCAL2 LOCAL      2%   OK  *
    *                         380F  PAGE.BT27.LOCAL3 LOCAL      2% *
    *                         OK  320F  PAGE.BT27.LOCAL4 PAGEDEL C *
    *                         OMMAND IS NOT ACTIVE','_F17=UPD: +IE *
    *                         E200I 13.51.18 DISPLAY ASM TYPE      *
    *                         FULL STAT   DEV  DATASET NAME PLPA   *
    *                         37%   OK  310F  PAGE      D        & *
    *                              m   & n 0  g\       D   D       *
    *                                                              *
    *                                                              *
    *                                                            Y *
    *                                                              *
    *                         ','_F18=IEE200I','_F19=2','_F21=TYPE *
    *                         ','_F22=CICS','_F23=FULL','_F24=CITL *
    *                         ' ;END                               *
    *                                                              *
    *                      4. The following error message can be   *
    *                         issued when Event Pump parameter     *
    *                         EXEC_REFRESH is NO:                  *
    *                                                              *
    *                         IRX0406E REXX exec load file AOPEXEC *
    *                         does not contain exec member         *
    *                         BPXWUNIX.                            *
    *                                                              *
    *                         The BPXWUNIX function resides in a   *
    *                         load library and program searches    *
    *                         the exec library first. The function *
    *                         can not be located there.            *
    *                         REXX issues the IRX0406E message     *
    *                         indicating the function was not      *
    *                         found in the exec library. Then it   *
    *                         searches the load libraries where    *
    *                         the function is successfully located *
    *                         and executed.                        *
    *                                                              *
    *                      5. Abend S0C1 can occur in GTMAOP96     *
    *                         module when it executes a CFI        *
    *                         instruction. The CFI instruction     *
    *                         has been added with OA36516(UA60674) *
    *                         but requires the Extended-Immediate  *
    *                         Facility. This facility has been     *
    *                         added only in the z9-109.            *
    ****************************************************************
    * RECOMMENDATION: Apply the applicable PTF.                    *
    ****************************************************************
    

Problem conclusion

  • The problems have been fixed.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA39339

  • Reported component name

    EVENT PUMP FOR

  • Reported component ID

    5698B3400

  • Reported release

    422

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2012-04-16

  • Closed date

    2012-06-08

  • Last modified date

    2013-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA65551

Modules/Macros

  • GPZAOPC1 GTMAOPA0 GTMAOPD3 GTMCTMON GTMCTSRP
    GTMRXCTP
    

Fix information

  • Fixed component name

    EVENT PUMP FOR

  • Fixed component ID

    5698B3400

Applicable component levels

  • R422 PSY UA65551

       UP13/01/15 P F301

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSXTW7","label":"Tivoli Event Pump for z\/OS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}},{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SG19M","label":"APARs - z\/OS environment"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"422","Edition":"","Line of Business":{"code":"","label":""}}]

Document Information

Modified date:
04 February 2013