Error description

  • NPM SMF type 28 Record Subtype x'DC' for SMF28VCS (VTAM
    Statistics Collection - CSM) ECSA buffer data mapped incorrectly
    by NPM
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of NetView Performance Monitor who *
    *                 gather Communicaions Server CSM              *
    *                 (Communications Storage Manager) statistics  *
    *                 using SMF.                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION: SMF record type 28 subtype 220 is built *
    *                      to record CSM storage usage data. It is *
    *                      meant to contain 4 buffer pools in the  *
    *                      address space and 4 buffer pools in a   *
    *                      data space. However, 5 address space    *
    *                      pools (of size 4K, 16K, 32K, 60K and    *
    *                      180K) and 3 data space pools (of size   *
    *                      4K, 16K and 32K) are recorded.          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    NPM was designed to record CSM buffer pools with sizes 4K, 16K,
    32K and 60K, in both CSM's address space and its data space.
    However, in a previous release of z/OS, CSM implemented an
    additional buffer pool of size 180K. When NPM requests and
    interprets the CSM buffer pool data retrieved from VTAM, it
    assumes there will be information about the 8 buffer pools that
    it is expecting, laid out sequentially. Because VTAM returned
    information about 10 buffer pools, NPM retrieves the first 8,
    which includes 5 pools from the address space and only 3 from
    the data space. This is reflected in SMF record 28 subtype 220.
    

Problem conclusion

  • Module FNMVTMC1 is being changed to check the buffer pool sizes
    that are returned from VTAM and to only pick up data that
    matches one of the 4 sizes for which NPM was designed to report.
    

Temporary fix

Comments

APAR Information

  • APAR number

    OA38371

  • Reported component name

    NPM V2 MVS

  • Reported component ID

    565504300

  • Reported release

    270

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2011-12-19

  • Closed date

    2012-02-15

  • Last modified date

    2012-03-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

    UA64216

Modules/Macros

  • FNMVTMC1 FNMVYDCP
    

Fix information

  • Fixed component name

    NPM V2 MVS

  • Fixed component ID

    565504300

Applicable component levels

  • R270 PSY UA64216

       UP12/03/01 P F202

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Tivoli NetView Performance Monitor

Software version:

270

Reference #:

OA38371

Modified date:

2012-03-01

Translate my page

Machine Translation

Content navigation