A fix is available
APAR status
Closed as program error.
Error description
Reduce cpu overhead for Omegamon II Storage light when real storage thresholds are not set.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All OMEGAMON II for MVS V550 users. * **************************************************************** * PROBLEM DESCRIPTION: 1. High cpu usage in the Omegamon * * Realtime Collector task when the * * Omegamon II Storage light is * * refreshed. * * 2. High cpu usage in the Omegamon * * Realtime Collector or TEMS tasks * * when the XCSA or XECS exceptions are * * invoked. * **************************************************************** * RECOMMENDATION: Apply the PTF. * **************************************************************** 1. In environments with a large amount of real storage, the code to report on real storage frames can use a lot of cpu. The code is run even when the thresholds for real storage use are not enabled. 2. The XCSA and XECS exceptions scan through every block of CSA and ECSA storage which can be cpu intensive.
Problem conclusion
1. Modify the code to only run the real storage analysis when the following Omegamon II real storage thresholds are set: Central storage online, Available frame queue low 2. Modify the code to use CSA/Analyzer data if available instead of scanning common storage control blocks. 550Y KM2001D KOMPWAI5 KOMWLM5 KOMXSY5
Temporary fix
********* * HIPER * ********* UNTIL THIS PTF IS APPLIED, THE FOLLOWING ACTIONS CAN REDUCE CPU. IN OMEGAMON II, TURN OFF THE STORAGE LIGHT IN THE TEP, DISABLE OR INCREASE THE INTERVAL TIME FOR SITUATIONS THAT MONITOR COMMON STORAGE.
Comments
APAR Information
APAR number
OA37647
Reported component name
OMEG II FOR MVS
Reported component ID
5608A0400
Reported release
550
Status
CLOSED PER
PE
NoPE
HIPER
YesHIPER
Special Attention
NoSpecatt
Submitted date
2011-09-23
Closed date
2011-10-28
Last modified date
2011-12-01
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA62873
Modules/Macros
KM2001D KOMPWAI5 KOMWLM5 KOMXSY5
Fix information
Fixed component name
OMEG II FOR MVS
Fixed component ID
5608A0400
Applicable component levels
R550 PSY UA62873
UP11/11/02 P F111
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU054","label":"Systems w\/TPS"},"Product":{"code":"SSNU68","label":"Tivoli OMEGAMON II for MVS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"550","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
01 December 2011