A fix is available
APAR status
Closed as program error.
Error description
NPM User Abend 0006 Csect FNMBUF10 PTF UA13922 is applied U0006 (X'0006') Explanation: The buffer manager found a buffer that was not used properly. Register 15 contains Reason Code 0C. Reason Code Explanation 0C The buffer scanner found a buffer that had been overlaid. RIDS/FNMXCEST Recovery routine csect name: FNMXCEST
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: All Tivoli NPM V2R7 users. * **************************************************************** * PROBLEM DESCRIPTION: When using TCP/IP sockets for * * communication and a malformed TCP/IP * * buffer is received, an ABENDU0006-0C * * may occur in FNMBUF10. * **************************************************************** * RECOMMENDATION: * **************************************************************** The malformed buffer had a length value in the buffer header greater than the actual buffer size and greater than the maximum size buffer expected. FNMTCP10 used the erroneous buffer length in the buffer header to move the buffer to another location in storage. This move caused the storage beyond the end of the target storage to be overlaid. The overlaid storage contained NPM storage management control blocks. The next time NPM requested storage from its storage manager, the overlay was detected and abend U0006-0C was issued.
Problem conclusion
FNMTCP10 is being changed to check the TCP/IP buffer header size value before the move causing the abend to ensure that it is less than or equal to the maximum expected. If the buffer length value exceeds the maximum, the socket connection will be closed.
Temporary fix
Comments
APAR Information
APAR number
OA37170
Reported component name
NPM V2 MVS
Reported component ID
565504300
Reported release
270
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2011-07-29
Closed date
2011-09-21
Last modified date
2011-10-04
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
UA62284
Modules/Macros
FNMTCP10
Fix information
Fixed component name
NPM V2 MVS
Fixed component ID
565504300
Applicable component levels
R270 PSY UA62284
UP11/09/29 P F109
Fix is available
Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSZJE6","label":"Tivoli NetView Performance Monitor"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"270","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date: