Error description

  • New Function
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED: All users of the IBM Tivoli System           *
    *                 Automation for z/OS releases 3.3 and 3.2,    *
    *                 planning to target a IBM zEnterprise System  *
    *                 with the following SA functions: ProcOps,    *
    *                 Lpar Management, or Parallel Sysplex         *
    *                 Enhancements.                                *
    *                                                              *
    *                 All GDPS users with the SA z/OS releases     *
    *                 3.3 or 3.2, planning to control a            *
    *                 IBM zEnterprise System.                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Exploit new functionality provided by   *
    *                      the hardware interface of SE/HMC        *
    *                      Consoles Version 2.11.x and later. The  *
    *                      new commands are available for System   *
    *                      z196 hardware only.                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Based on new functions provided by the System z - Application
    Programming Interface, the following Processor Operations
    Common Commands have been added (new command) or modified:
    
    - New command POWERMOD. This command can be used to perform a
      query or change of a CPC's Power Mode settings. In addition
      to the new hardware function, new event filter is introduced
      to register for power mode change events.
      The new events are displayed as AOFA0300 reports.
    
    - Change to command ICNTL (Image Control): new parameter for
      Group Capacity 'GRPCAP' is added; with the new parameter,
      users can query the current Group Capacity value of the
      capacity group the Image  belongs to and change its value
      at runtime.
    

Problem conclusion

Temporary fix

Comments

  • The major code changes were preformed for the following modules:
    
    - C-module INGCHW0D: implement code for new POWERMOD command,
      implement code for new ICNTL 'GRPCAP' parameter, implement
      code for new FILTER command parameter 'PW' (power mode change
      ebents).
    
    - C-module INGCHW0E: Rework System z API Condition Code
      reporting (0B10xxx messages) for new POWERMOD common
      command. Implement code for new Report AOFA0300.
    
    - REXX-module INGRX810: implement code for new command
      POWRERMOD; implement code for ne ICNTL command parameter
      'GRPCAP'.
    
    - REXX-module ISQCCMD: implement code for new command
      POWRERMOD; implement code for ne ICNTL command parameter
      'GRPCAP'
    
    In addition, Processor Operations online help (NetView
    command ISQHELP) was updated with the new/changed common
    commands.
    

APAR Information

  • APAR number

    OA33589

  • Reported component name

    SYSTEM AUTO Z/O

  • Reported component ID

    5698SA300

  • Reported release

    320

  • Status

    CLOSED UR1

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2010-07-12

  • Closed date

    2010-09-29

  • Last modified date

    2010-11-02

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • AOFA002  AOFHELPP DSIISQ32 HSACHTTI INGCHW00
    INGHPROC INGHW0VN INGRX810 ISQCCMD  ISQGPWR  ISQGSNCS ISQH$GEN
    ISQSNMPI ISQ32
    

Publications Referenced
SC33826505 SC34257500 SC33826405 SC34257400  

Fix information

  • Fixed component name

    SYSTEM AUTO Z/O

  • Fixed component ID

    5698SA300

Applicable component levels

  • R310 PSY UA56889

       UP10/10/05 P F010

  • R320 PSY UA56905

       UP10/10/05 P F010

  • R330 PSY UA56906

       UP10/10/05 P F010

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Rate this page:

(0 users)Average rating

Add comments

Document information


More support for:

Tivoli System Automation for z/OS

Software version:

320

Reference #:

OA33589

Modified date:

2010-11-02

Translate my page

Machine Translation

Content navigation